#TITLE_ALTERNATIVE#
Tools to be used to measure body weight and to measure gravity acceleration by using sensor LVDT is presented. By giving mass to load spot, ferro core (armature) at LVDT will be displace and generate the changing in voltage, This changing is used to convert voltage to weight. <br /> <br...
محفوظ في:
المؤلف الرئيسي: | |
---|---|
التنسيق: | Theses |
اللغة: | Indonesia |
الوصول للمادة أونلاين: | https://digilib.itb.ac.id/gdl/view/20823 |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
المؤسسة: | Institut Teknologi Bandung |
اللغة: | Indonesia |
الملخص: | Tools to be used to measure body weight and to measure gravity acceleration by using sensor LVDT is presented. By giving mass to load spot, ferro core (armature) at LVDT will be displace and generate the changing in voltage, This changing is used to convert voltage to weight. <br />
<br />
<br />
From the experiment, we get spring constant k=96,63 N/m with the sensivity of LVDT M=0,049 m/Volt. From linearity regression of the data experiment we get W = 4,5161 Vo + 4,1164. By comparing of weight measuring and counting we get error 7,545619 %, average of gravity acceleration is 9,32657 m/s2 with error 4,83082 %. |
---|