PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA

Background: Minimalization of Dose Length Product (DLP) and image noise can be obtained from the use of appropriate methods with the examination done. One method to minimize the radiation dose is Reduce Dose. Then there are several methods to reduce image noise and Iterative Reconstruction (IR) meth...

Full description

Saved in:
Bibliographic Details
Main Author: ULIL ALIIFAH PUTRI, 15161383046
Format: Theses and Dissertations NonPeerReviewed
Language:Indonesian
Indonesian
Published: 2018
Subjects:
Online Access:http://repository.unair.ac.id/77438/1/FV.RD.%2010-18%20Put%20p%20Abstrak.pdf
http://repository.unair.ac.id/77438/2/FV.RD.%2010-18%20Put%20p.pdf
http://repository.unair.ac.id/77438/
http://lib.unair.ac.id
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Airlangga
Language: Indonesian
Indonesian
id id-langga.77438
record_format dspace
spelling id-langga.774382019-01-02T02:50:01Z http://repository.unair.ac.id/77438/ PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA ULIL ALIIFAH PUTRI, 15161383046 RC71-78.7 Examination. Diagnosis Including radiography Background: Minimalization of Dose Length Product (DLP) and image noise can be obtained from the use of appropriate methods with the examination done. One method to minimize the radiation dose is Reduce Dose. Then there are several methods to reduce image noise and Iterative Reconstruction (IR) method is used. One of the Iterative Reconstruction methods found in the Philips 128 Slices MSCT tool is iDose. This study intends to obtain an optimal Reduce Dose level in reducing dosage and iDose levels capable of minimizing image noise. Purpose: To know the differences of Dose Length Product (DLP) and Image Noise by using variation method of Reduce Dose and Iterative Reconstruction (IR). Result: In the increasing variation of Reduce Dose, there is a difference of Dose Length Product (DLP) which is also increasing. Increasing DLP value is in line with the decreased image noise value. The most minimal increase in the dose of radiation is found in the variation of Reduce Dose 34 with a 2.2% increase. The most minimal image noise value is at iDose level 5. Among the three variations of Reduce Dose, the level that reduces image noise most is Reduce Dose 34. Conclusion:There are several differences of Dose Length Product (DLP) and Image noise values with variation of Reduce Dose and Iterative Reconstruction methods. Based on experiment, Reduce Dose 34 and iDose 5 has chosen as the optimal level in radiation dose and image noise. This levels gives optimal dose with minimal image noise values. 2018 Thesis NonPeerReviewed text id http://repository.unair.ac.id/77438/1/FV.RD.%2010-18%20Put%20p%20Abstrak.pdf text id http://repository.unair.ac.id/77438/2/FV.RD.%2010-18%20Put%20p.pdf ULIL ALIIFAH PUTRI, 15161383046 (2018) PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA. Skripsi thesis, Universitas Airlangga. http://lib.unair.ac.id
institution Universitas Airlangga
building Universitas Airlangga Library
country Indonesia
collection UNAIR Repository
language Indonesian
Indonesian
topic RC71-78.7 Examination. Diagnosis Including radiography
spellingShingle RC71-78.7 Examination. Diagnosis Including radiography
ULIL ALIIFAH PUTRI, 15161383046
PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
description Background: Minimalization of Dose Length Product (DLP) and image noise can be obtained from the use of appropriate methods with the examination done. One method to minimize the radiation dose is Reduce Dose. Then there are several methods to reduce image noise and Iterative Reconstruction (IR) method is used. One of the Iterative Reconstruction methods found in the Philips 128 Slices MSCT tool is iDose. This study intends to obtain an optimal Reduce Dose level in reducing dosage and iDose levels capable of minimizing image noise. Purpose: To know the differences of Dose Length Product (DLP) and Image Noise by using variation method of Reduce Dose and Iterative Reconstruction (IR). Result: In the increasing variation of Reduce Dose, there is a difference of Dose Length Product (DLP) which is also increasing. Increasing DLP value is in line with the decreased image noise value. The most minimal increase in the dose of radiation is found in the variation of Reduce Dose 34 with a 2.2% increase. The most minimal image noise value is at iDose level 5. Among the three variations of Reduce Dose, the level that reduces image noise most is Reduce Dose 34. Conclusion:There are several differences of Dose Length Product (DLP) and Image noise values with variation of Reduce Dose and Iterative Reconstruction methods. Based on experiment, Reduce Dose 34 and iDose 5 has chosen as the optimal level in radiation dose and image noise. This levels gives optimal dose with minimal image noise values.
format Theses and Dissertations
NonPeerReviewed
author ULIL ALIIFAH PUTRI, 15161383046
author_facet ULIL ALIIFAH PUTRI, 15161383046
author_sort ULIL ALIIFAH PUTRI, 15161383046
title PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
title_short PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
title_full PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
title_fullStr PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
title_full_unstemmed PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA
title_sort perbandingan variasi reduce dose dan iterative reconstruction (ir) dalam menentukan minimalisasi dose length product (dlp) dan image noise ct scan kepala
publishDate 2018
url http://repository.unair.ac.id/77438/1/FV.RD.%2010-18%20Put%20p%20Abstrak.pdf
http://repository.unair.ac.id/77438/2/FV.RD.%2010-18%20Put%20p.pdf
http://repository.unair.ac.id/77438/
http://lib.unair.ac.id
_version_ 1681150773532033024