Morphometric study of atypical lumbar vertebrae and its physiological correlation
Background: The fixation of lumbar spine is needed for various spinal problems such as fracture in lumbar spine, resection of tumors in vertebral bodies, gross spondylolisthesis, and lumbar instabilities. Majority of pedicle morphometric studies are based on white population in different parts of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Kebangsaan Malaysia
2015
|
Online Access: | http://journalarticle.ukm.my/8780/1/P.262-265.pdf http://journalarticle.ukm.my/8780/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Kebangsaan Malaysia |
Language: | English |
id |
my-ukm.journal.8780 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.87802016-12-14T06:48:08Z http://journalarticle.ukm.my/8780/ Morphometric study of atypical lumbar vertebrae and its physiological correlation Amrish Tiwari, Shilpa Pandey, Deepak C Naik, Background: The fixation of lumbar spine is needed for various spinal problems such as fracture in lumbar spine, resection of tumors in vertebral bodies, gross spondylolisthesis, and lumbar instabilities. Majority of pedicle morphometric studies are based on white population in different parts of the world, whereas only a few studies are available on Indian population. Objective: To report the results of a morphometric study of adult atypical lumbar vertebrae’s pedicles and correlate them physiologically to provide morphometric inputs for the use of this vertebral component in implants fixation in the population of Rewa, Madhya Pradesh, India. Materials and Methods: This study was conducted on 20 dry human atypical lumbar vertebrae obtained from Department of Anatomy, Shyam Shah Medical College, Rewa (Madhya Pradesh, India). Pedicle vertical height (h) and pedicle width (w) were measured with the help of a sliding vernier caliper. Results: Positive correlations have been found between height and width of dry human lumbar vertebrae. Conclusion: Results indicated that in Rewa region of central India, 15-mm Steffee pedicle screw can be used safely for atypical lumbar vertebrae. Universiti Kebangsaan Malaysia 2015-06-17 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/8780/1/P.262-265.pdf Amrish Tiwari, and Shilpa Pandey, and Deepak C Naik, (2015) Morphometric study of atypical lumbar vertebrae and its physiological correlation. International Journal of Public Health Research, 4 (2). pp. 262-265. ISSN 2232-0245 www.ijphr.ukm.my |
institution |
Universiti Kebangsaan Malaysia |
building |
Perpustakaan Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
Background: The fixation of lumbar spine is needed for various spinal problems such as fracture in lumbar spine,
resection of tumors in vertebral bodies, gross spondylolisthesis, and lumbar instabilities. Majority of pedicle morphometric
studies are based on white population in different parts of the world, whereas only a few studies are available on Indian
population.
Objective: To report the results of a morphometric study of adult atypical lumbar vertebrae’s pedicles and correlate them
physiologically to provide morphometric inputs for the use of this vertebral component in implants fixation in the population
of Rewa, Madhya Pradesh, India.
Materials and Methods: This study was conducted on 20 dry human atypical lumbar vertebrae obtained from Department
of Anatomy, Shyam Shah Medical College, Rewa (Madhya Pradesh, India). Pedicle vertical height (h) and pedicle width (w)
were measured with the help of a sliding vernier caliper.
Results: Positive correlations have been found between height and width of dry human lumbar vertebrae.
Conclusion: Results indicated that in Rewa region of central India, 15-mm Steffee pedicle screw can be used safely for
atypical lumbar vertebrae. |
format |
Article |
author |
Amrish Tiwari, Shilpa Pandey, Deepak C Naik, |
spellingShingle |
Amrish Tiwari, Shilpa Pandey, Deepak C Naik, Morphometric study of atypical lumbar vertebrae and its physiological correlation |
author_facet |
Amrish Tiwari, Shilpa Pandey, Deepak C Naik, |
author_sort |
Amrish Tiwari, |
title |
Morphometric study of atypical lumbar vertebrae
and its physiological correlation |
title_short |
Morphometric study of atypical lumbar vertebrae
and its physiological correlation |
title_full |
Morphometric study of atypical lumbar vertebrae
and its physiological correlation |
title_fullStr |
Morphometric study of atypical lumbar vertebrae
and its physiological correlation |
title_full_unstemmed |
Morphometric study of atypical lumbar vertebrae
and its physiological correlation |
title_sort |
morphometric study of atypical lumbar vertebrae
and its physiological correlation |
publisher |
Universiti Kebangsaan Malaysia |
publishDate |
2015 |
url |
http://journalarticle.ukm.my/8780/1/P.262-265.pdf http://journalarticle.ukm.my/8780/ |
_version_ |
1643737583483617280 |