Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities
Reliability block diagram assessment of ethylene oxide production facilities. Having a maintenance plan by referring to the OEM manual is not the optimum time interval. The manual usually created to follow the failure rate of the equipment in a general operating range and condition, and tested indep...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi Petronas
2011
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/2687/1/DISSERTATION_NASHAKIR_10719.pdf http://utpedia.utp.edu.my/2687/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
Language: | English |
id |
my-utp-utpedia.2687 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.26872017-01-25T09:41:42Z http://utpedia.utp.edu.my/2687/ Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities Mohamad Nashakir bin Md Dom, Mohamad Nashakir TJ Mechanical engineering and machinery Reliability block diagram assessment of ethylene oxide production facilities. Having a maintenance plan by referring to the OEM manual is not the optimum time interval. The manual usually created to follow the failure rate of the equipment in a general operating range and condition, and tested independently. Difficulty in having optimal maintenance plan is the accuracy of the data and the equipment modeling. Accuracy in the data usually is very low therefore creating optimum strategy is the best solution. In the study component prioritization is the strategy based on risk. Focused on the developing the reliability block diagram for the ethylene oxide production facilities. Universiti Teknologi Petronas 2011-09 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/2687/1/DISSERTATION_NASHAKIR_10719.pdf Mohamad Nashakir bin Md Dom, Mohamad Nashakir (2011) Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities. Universiti Teknologi Petronas, Sri Iskandar, Tronoh, Perak. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Mohamad Nashakir bin Md Dom, Mohamad Nashakir Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
description |
Reliability block diagram assessment of ethylene oxide production facilities. Having a maintenance plan by referring to the OEM manual is not the optimum time interval. The manual usually created to follow the failure rate of the equipment in a general operating range and condition, and tested independently. Difficulty in having optimal maintenance plan is the accuracy of the data and the equipment modeling. Accuracy in the data usually is very low therefore creating optimum strategy is the best solution. In the study component prioritization is the strategy based on risk. Focused on the developing the
reliability block diagram for the ethylene oxide production facilities. |
format |
Final Year Project |
author |
Mohamad Nashakir bin Md Dom, Mohamad Nashakir |
author_facet |
Mohamad Nashakir bin Md Dom, Mohamad Nashakir |
author_sort |
Mohamad Nashakir bin Md Dom, Mohamad Nashakir |
title |
Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
title_short |
Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
title_full |
Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
title_fullStr |
Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
title_full_unstemmed |
Reliability Block Diagram Assessment of Ethylene Oxide Production Facilities |
title_sort |
reliability block diagram assessment of ethylene oxide production facilities |
publisher |
Universiti Teknologi Petronas |
publishDate |
2011 |
url |
http://utpedia.utp.edu.my/2687/1/DISSERTATION_NASHAKIR_10719.pdf http://utpedia.utp.edu.my/2687/ |
_version_ |
1739830946207629312 |