Ventilation performance assessment of an educational building in a hot and humid climate

Air Handling Units in mechanical ventilation system possess a high degree of potential to circulate contaminants within occupied spaces of a building which often results in sick building syndrome (SBS), building related illness (BRI) and other indoor air quality (IAQ) related issues. This happens de...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali, Maisarah, Oladokun, Majeed, Osman, Samsul Bahrin, Samsuddin, Niza, Hamzah, Hairul Aini, Salleh, Md. Noor
Format: Conference or Workshop Item
Language:English
English
Published: Springer 2015
Subjects:
Online Access:http://irep.iium.edu.my/39912/7/39912.pdf
http://irep.iium.edu.my/39912/8/2014front-InCiec.pdf
http://irep.iium.edu.my/39912/
http://link.springer.com/chapter/10.1007%2F978-981-287-290-6_29
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.39912
record_format dspace
spelling my.iium.irep.399122020-12-30T07:25:00Z http://irep.iium.edu.my/39912/ Ventilation performance assessment of an educational building in a hot and humid climate Ali, Maisarah Oladokun, Majeed Osman, Samsul Bahrin Samsuddin, Niza Hamzah, Hairul Aini Salleh, Md. Noor NA Architecture QR Microbiology RZ Other systems of medicine TH Building construction Air Handling Units in mechanical ventilation system possess a high degree of potential to circulate contaminants within occupied spaces of a building which often results in sick building syndrome (SBS), building related illness (BRI) and other indoor air quality (IAQ) related issues. This happens despite the expected role of ventilation systems to create a balance of thermal comfort and indoor air quality to the building occupants as well as the stored components. In the hot and humid climate mechanical ventilation systems play an important role of controlling the indoor hygrothermal conditions. Inadequate performance of the mechanical ventilation systems result in several issues ranging from human occupants discomfort, mechanical damages to archival materials and mould problem amongst others. This study presents the measurement and analysis of the mechanical ventilation systems’ performance and its effect on various indoor spaces in an academic building in Malaysia. Measurement of airflow, thermal and hygric conditions of the facility together with the aero-biological sampling were executed. The ventilation performance assessment revealed that the AHU fails in its cooling and dehumidification capacities as most of the occupied zones witnessed elevated humidity and low temperature and hence poor hygrothermal performance. On the other hand, results of bio-aerosol assessment indicates that the AHU performs well in its decontamination capacities by reducing the microbial level between the AHU and the occupied zones. The dominant species of mould in the assessed spaces are Penicillium sp., Yeast, Cladosporium sp., and Chaetomium sp. with 100% occurrence in all the assessed space. On the other hand, Black Mold, Syntalidium sp., and zygomycetes are the least species in spaces with 25% occurrence. The presence of black mould portends a great danger to the occupants’ health and therefore requires urgent attention. Keywords—Ventilation performance, bio-aerosol Assessment, Indoor Air Quality, Building Related Illness, Hygrothermal Performance, Cooling and Dehumidification. Springer 2015 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/39912/7/39912.pdf application/pdf en http://irep.iium.edu.my/39912/8/2014front-InCiec.pdf Ali, Maisarah and Oladokun, Majeed and Osman, Samsul Bahrin and Samsuddin, Niza and Hamzah, Hairul Aini and Salleh, Md. Noor (2015) Ventilation performance assessment of an educational building in a hot and humid climate. In: International Civil and Infrastructure Engineering Conference 2014, 28 September - 1 October 2014 , Kota Kinabalu, Sabah Malaysia. http://link.springer.com/chapter/10.1007%2F978-981-287-290-6_29 #155
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic NA Architecture
QR Microbiology
RZ Other systems of medicine
TH Building construction
spellingShingle NA Architecture
QR Microbiology
RZ Other systems of medicine
TH Building construction
Ali, Maisarah
Oladokun, Majeed
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
Ventilation performance assessment of an educational building in a hot and humid climate
description Air Handling Units in mechanical ventilation system possess a high degree of potential to circulate contaminants within occupied spaces of a building which often results in sick building syndrome (SBS), building related illness (BRI) and other indoor air quality (IAQ) related issues. This happens despite the expected role of ventilation systems to create a balance of thermal comfort and indoor air quality to the building occupants as well as the stored components. In the hot and humid climate mechanical ventilation systems play an important role of controlling the indoor hygrothermal conditions. Inadequate performance of the mechanical ventilation systems result in several issues ranging from human occupants discomfort, mechanical damages to archival materials and mould problem amongst others. This study presents the measurement and analysis of the mechanical ventilation systems’ performance and its effect on various indoor spaces in an academic building in Malaysia. Measurement of airflow, thermal and hygric conditions of the facility together with the aero-biological sampling were executed. The ventilation performance assessment revealed that the AHU fails in its cooling and dehumidification capacities as most of the occupied zones witnessed elevated humidity and low temperature and hence poor hygrothermal performance. On the other hand, results of bio-aerosol assessment indicates that the AHU performs well in its decontamination capacities by reducing the microbial level between the AHU and the occupied zones. The dominant species of mould in the assessed spaces are Penicillium sp., Yeast, Cladosporium sp., and Chaetomium sp. with 100% occurrence in all the assessed space. On the other hand, Black Mold, Syntalidium sp., and zygomycetes are the least species in spaces with 25% occurrence. The presence of black mould portends a great danger to the occupants’ health and therefore requires urgent attention. Keywords—Ventilation performance, bio-aerosol Assessment, Indoor Air Quality, Building Related Illness, Hygrothermal Performance, Cooling and Dehumidification.
format Conference or Workshop Item
author Ali, Maisarah
Oladokun, Majeed
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
author_facet Ali, Maisarah
Oladokun, Majeed
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
author_sort Ali, Maisarah
title Ventilation performance assessment of an educational building in a hot and humid climate
title_short Ventilation performance assessment of an educational building in a hot and humid climate
title_full Ventilation performance assessment of an educational building in a hot and humid climate
title_fullStr Ventilation performance assessment of an educational building in a hot and humid climate
title_full_unstemmed Ventilation performance assessment of an educational building in a hot and humid climate
title_sort ventilation performance assessment of an educational building in a hot and humid climate
publisher Springer
publishDate 2015
url http://irep.iium.edu.my/39912/7/39912.pdf
http://irep.iium.edu.my/39912/8/2014front-InCiec.pdf
http://irep.iium.edu.my/39912/
http://link.springer.com/chapter/10.1007%2F978-981-287-290-6_29
_version_ 1688547718329270272