The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong

The research work reported in this paper investigates the numerical study on the influence of statistical moments of probability density function of R32 tube-side flow maldistribution on the thermal performance of microchannel heat exchanger. A model without considering superheat and sub-cool was de...

Full description

Saved in:
Bibliographic Details
Main Authors: Chng, Ming Hui, Chin, Wai Meng, Tang, Sai Hong
Format: Article
Language:English
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2017
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/21118/1/AJ_Chng%20Ming%20Hui%20JME%2017.pdf
http://ir.uitm.edu.my/id/eprint/21118/
https://jmeche.uitm.edu.my/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.21118
record_format eprints
spelling my.uitm.ir.211182018-10-24T02:16:43Z http://ir.uitm.edu.my/id/eprint/21118/ The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong Chng, Ming Hui Chin, Wai Meng Tang, Sai Hong Thermodynamics Thermal conductivity The research work reported in this paper investigates the numerical study on the influence of statistical moments of probability density function of R32 tube-side flow maldistribution on the thermal performance of microchannel heat exchanger. A model without considering superheat and sub-cool was developed to analyze the effect of mean, standard deviation and skew of the refrigerant maldistribution profile on the heating capacity degradation of the heat exchanger. Next, the performance degradation of microchannel heat exchanger due to refrigerant (R32) maldistribution was quantified and analyzed. After that, the model was validated by doing experiment. Finally, a performance deterioration correlation related to refrigerant maldistribution without considering superheat and sub-cool was developed to offer a faster and simpler method to analyze the maldistribution problem. It is found that mean and standard deviation have the highest impact on the performance deterioration. Maldistribution with high standard deviation and high negative skew gives a large magnitude of performance deterioration. For standard deviation more than 0.3, the deterioration can up to 1%. Besides that, the deterioration reaches 1% for skew below -0.5. Furthermore, the deterioration is as high as 4% when the mean is less than 0.9. Hence, the first three moments such as mean, standard deviation and skew should be optimized in the effort of improve the thermal performance of the heat exchanger. The proposed correlation in this work offers a faster and simpler method for a quick estimate of the degradation factor. Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2017 Article PeerReviewed text en http://ir.uitm.edu.my/id/eprint/21118/1/AJ_Chng%20Ming%20Hui%20JME%2017.pdf Chng, Ming Hui and Chin, Wai Meng and Tang, Sai Hong (2017) The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong. Journal of Mechanical Engineering (JMechE), 14 (2). pp. 149-166. ISSN 1823-5514 ; 2550-164X https://jmeche.uitm.edu.my/
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Thermodynamics
Thermal conductivity
spellingShingle Thermodynamics
Thermal conductivity
Chng, Ming Hui
Chin, Wai Meng
Tang, Sai Hong
The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
description The research work reported in this paper investigates the numerical study on the influence of statistical moments of probability density function of R32 tube-side flow maldistribution on the thermal performance of microchannel heat exchanger. A model without considering superheat and sub-cool was developed to analyze the effect of mean, standard deviation and skew of the refrigerant maldistribution profile on the heating capacity degradation of the heat exchanger. Next, the performance degradation of microchannel heat exchanger due to refrigerant (R32) maldistribution was quantified and analyzed. After that, the model was validated by doing experiment. Finally, a performance deterioration correlation related to refrigerant maldistribution without considering superheat and sub-cool was developed to offer a faster and simpler method to analyze the maldistribution problem. It is found that mean and standard deviation have the highest impact on the performance deterioration. Maldistribution with high standard deviation and high negative skew gives a large magnitude of performance deterioration. For standard deviation more than 0.3, the deterioration can up to 1%. Besides that, the deterioration reaches 1% for skew below -0.5. Furthermore, the deterioration is as high as 4% when the mean is less than 0.9. Hence, the first three moments such as mean, standard deviation and skew should be optimized in the effort of improve the thermal performance of the heat exchanger. The proposed correlation in this work offers a faster and simpler method for a quick estimate of the degradation factor.
format Article
author Chng, Ming Hui
Chin, Wai Meng
Tang, Sai Hong
author_facet Chng, Ming Hui
Chin, Wai Meng
Tang, Sai Hong
author_sort Chng, Ming Hui
title The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
title_short The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
title_full The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
title_fullStr The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
title_full_unstemmed The influence of refrigerant (R32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / Chng Ming Hui, Chin Wai Meng and Tang Sai Hong
title_sort influence of refrigerant (r32) flow maldistribution on the thermal performance of a microchannel heat exchanger without considering superheat and sub-cool / chng ming hui, chin wai meng and tang sai hong
publisher Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM)
publishDate 2017
url http://ir.uitm.edu.my/id/eprint/21118/1/AJ_Chng%20Ming%20Hui%20JME%2017.pdf
http://ir.uitm.edu.my/id/eprint/21118/
https://jmeche.uitm.edu.my/
_version_ 1685649424354639872