Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman

Dyes are aromatic organic compound which have an affinity towards the substrate to which they are being applied to. The presence of dyes in wastewater samples is not safe for human even at low level. The presence of dyes in wastewater which are discharged from textile industry must be analysed. Henc...

Full description

Saved in:
Bibliographic Details
Main Authors: Zainudin, Nur Syamimi, Abdul Rahman, Nur Aqilah
Format: Article
Language:English
Published: Universiti Teknologi MARA Negeri Sembilan 2021
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/47824/1/47824.pdf
http://ir.uitm.edu.my/id/eprint/47824/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.47824
record_format eprints
spelling my.uitm.ir.478242021-06-21T03:22:26Z http://ir.uitm.edu.my/id/eprint/47824/ Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman Zainudin, Nur Syamimi Abdul Rahman, Nur Aqilah Industrial safety. Industrial accident prevention Carbon, Activated Textile bleaching, dyeing, printing, etc. Dyes are aromatic organic compound which have an affinity towards the substrate to which they are being applied to. The presence of dyes in wastewater samples is not safe for human even at low level. The presence of dyes in wastewater which are discharged from textile industry must be analysed. Hence, a precise, fast, accurate, simple and inexpensive analytical method with low detection limit is needed for the determination of dyes in wastewaters. The differential pulse anodic stripping voltammetric (DPASV) technique using bare glassy carbon electrode (GCE) as a working electrode and phosphate buffer at pH 4.2 as a supporting electrolyte has been proposed for Reactive Black 5 (RB5) determination. Several experimental voltammetric parameters were being optimized for obtaining a maximum response before analytical validation of the proposed technique being carried out. The optimum parameters were initial potential (Ei) = +0.3 V, end potential (Ef) = +1.0 V, scan rate (v) = 0.04 V/s, accumulation time (tacc) = 50 s, accumulation potential (Eacc) = 0.4 V and pulse amplitude = 0.075 V. The well-defined anodic peak appeared at 0.77972 V. The response was linear from 0.5 to 1.25 mg/L (R2=0.9986) with LOD of 0.050 mg/L. The relative standard deviation (RSD) achieved were 0.08 %, 0.62 % and 0.50 %, respectively for three consecutive days. The % recovery range achieved was from 89.71 % to 111.15 %. It can be concluded that the proposed technique is precise, accurate, inexpensive, fast and has a potential to be an alternative analytical technique for RB5 analysis. The proposed method will in the future be tested for the amount of RB5 in the wastewater samples from textile industry. Universiti Teknologi MARA Negeri Sembilan 2021 Article PeerReviewed text en http://ir.uitm.edu.my/id/eprint/47824/1/47824.pdf ID47824 Zainudin, Nur Syamimi and Abdul Rahman, Nur Aqilah (2021) Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman. Journal of Academia, 9. pp. 73-79. ISSN 2289-6368
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Industrial safety. Industrial accident prevention
Carbon, Activated
Textile bleaching, dyeing, printing, etc.
spellingShingle Industrial safety. Industrial accident prevention
Carbon, Activated
Textile bleaching, dyeing, printing, etc.
Zainudin, Nur Syamimi
Abdul Rahman, Nur Aqilah
Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
description Dyes are aromatic organic compound which have an affinity towards the substrate to which they are being applied to. The presence of dyes in wastewater samples is not safe for human even at low level. The presence of dyes in wastewater which are discharged from textile industry must be analysed. Hence, a precise, fast, accurate, simple and inexpensive analytical method with low detection limit is needed for the determination of dyes in wastewaters. The differential pulse anodic stripping voltammetric (DPASV) technique using bare glassy carbon electrode (GCE) as a working electrode and phosphate buffer at pH 4.2 as a supporting electrolyte has been proposed for Reactive Black 5 (RB5) determination. Several experimental voltammetric parameters were being optimized for obtaining a maximum response before analytical validation of the proposed technique being carried out. The optimum parameters were initial potential (Ei) = +0.3 V, end potential (Ef) = +1.0 V, scan rate (v) = 0.04 V/s, accumulation time (tacc) = 50 s, accumulation potential (Eacc) = 0.4 V and pulse amplitude = 0.075 V. The well-defined anodic peak appeared at 0.77972 V. The response was linear from 0.5 to 1.25 mg/L (R2=0.9986) with LOD of 0.050 mg/L. The relative standard deviation (RSD) achieved were 0.08 %, 0.62 % and 0.50 %, respectively for three consecutive days. The % recovery range achieved was from 89.71 % to 111.15 %. It can be concluded that the proposed technique is precise, accurate, inexpensive, fast and has a potential to be an alternative analytical technique for RB5 analysis. The proposed method will in the future be tested for the amount of RB5 in the wastewater samples from textile industry.
format Article
author Zainudin, Nur Syamimi
Abdul Rahman, Nur Aqilah
author_facet Zainudin, Nur Syamimi
Abdul Rahman, Nur Aqilah
author_sort Zainudin, Nur Syamimi
title Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
title_short Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
title_full Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
title_fullStr Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
title_full_unstemmed Determination of Reactive Black 5 (RB5) by differential pulse anodic stripping voltammetric technique / Nur Syamimi Zainudin and Nur Aqilah Abdul Rahman
title_sort determination of reactive black 5 (rb5) by differential pulse anodic stripping voltammetric technique / nur syamimi zainudin and nur aqilah abdul rahman
publisher Universiti Teknologi MARA Negeri Sembilan
publishDate 2021
url http://ir.uitm.edu.my/id/eprint/47824/1/47824.pdf
http://ir.uitm.edu.my/id/eprint/47824/
_version_ 1703963485921083392