Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah
Night ventilation is very important to achieve passive indoor cooling in the building and also give huge impact to human comfort. However, poor ventilation can contribute to several issues involving health issue caused by air pollutant inside the house is not removed properly. This report is focused...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2016
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/56332/1/56332.pdf https://ir.uitm.edu.my/id/eprint/56332/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Mara |
Language: | English |
id |
my.uitm.ir.56332 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.563322022-03-06T00:50:35Z https://ir.uitm.edu.my/id/eprint/56332/ Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah Abdullah, Mohammad Ali TH Building construction Heating and ventilation. Air conditioning Night ventilation is very important to achieve passive indoor cooling in the building and also give huge impact to human comfort. However, poor ventilation can contribute to several issues involving health issue caused by air pollutant inside the house is not removed properly. This report is focused on the effectiveness of passive cooling in residential house through effect of night ventilation. Several case studies was conducted at Seri Iskandar, Perak that can be classified into three (3) different types of residential houses design and layout which is single storey terrace house, double storey terrace house and single storey terrace house with air well. Finding revealed that the design and layout of the building affect the effectiveness of the passive indoor cooling in residential houses. Therefore, this report will discuss on the identifying the air velocity and relative humidity rate by using Velocicalc Plus Air Velocity Meter. The data collected had been analyzed to recognize which type of layout was the significant to achieve passive indoor cooling in the residential house. 2016 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/56332/1/56332.pdf ID56332 Abdullah, Mohammad Ali (2016) Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah. [Student Project] |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
TH Building construction Heating and ventilation. Air conditioning |
spellingShingle |
TH Building construction Heating and ventilation. Air conditioning Abdullah, Mohammad Ali Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
description |
Night ventilation is very important to achieve passive indoor cooling in the building and also give huge impact to human comfort. However, poor ventilation can contribute to several issues involving health issue caused by air pollutant inside the house is not removed properly. This report is focused on the effectiveness of passive cooling in residential house through effect of night ventilation. Several case studies was conducted at Seri Iskandar, Perak that can be classified into three (3) different types of residential houses design and layout which is single storey terrace
house, double storey terrace house and single storey terrace house with air well. Finding revealed that the design and layout of the building affect the effectiveness of the passive indoor cooling in residential houses. Therefore, this report will discuss on the identifying the air velocity and relative humidity rate by using Velocicalc Plus Air Velocity Meter. The data collected had been analyzed to recognize which type of layout was the significant to achieve passive indoor cooling in the residential house. |
format |
Student Project |
author |
Abdullah, Mohammad Ali |
author_facet |
Abdullah, Mohammad Ali |
author_sort |
Abdullah, Mohammad Ali |
title |
Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
title_short |
Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
title_full |
Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
title_fullStr |
Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
title_full_unstemmed |
Night ventilation for passive indoor cooling in residential house / Mohammad Ali Abdullah |
title_sort |
night ventilation for passive indoor cooling in residential house / mohammad ali abdullah |
publishDate |
2016 |
url |
https://ir.uitm.edu.my/id/eprint/56332/1/56332.pdf https://ir.uitm.edu.my/id/eprint/56332/ |
_version_ |
1726795673843531776 |