Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard

Transformers need to be protected not only from internal short circuits, but also from abnormal operating Conditions, such as over loading, inrush currents, go-through faults and surges. The simplest but extremely effective form of protection is the electromechanical relay, which closes contacts and...

Full description

Saved in:
Bibliographic Details
Main Author: Fard, Ali Asghar Fathollahi
Format: Conference or Workshop Item
Language:English
Published: 2006
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/81834/1/81834.PDF
https://ir.uitm.edu.my/id/eprint/81834/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.81834
record_format eprints
spelling my.uitm.ir.818342023-10-27T07:38:46Z https://ir.uitm.edu.my/id/eprint/81834/ Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard Fard, Ali Asghar Fathollahi Electric apparatus and materials. Electric circuits. Electric networks Transformers need to be protected not only from internal short circuits, but also from abnormal operating Conditions, such as over loading, inrush currents, go-through faults and surges. The simplest but extremely effective form of protection is the electromechanical relay, which closes contacts and hence energizes the circuit-breaker opening mechanisms when currents larger than allowed values pass through. In a power system, the differential relay should operate only in its indicated protection zone, and not for out of its protection zone. This paper will focus on the problem, where the differential relay (87) indiscriminately functions for its out of protection zone. Effect of mismatching currents has been considered. 2006 Conference or Workshop Item PeerReviewed text en https://ir.uitm.edu.my/id/eprint/81834/1/81834.PDF Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard. (2006) In: Volume No. 1: Science and Technology, 30 – 31 May 2006, Swiss Garden Resort & Spa Kuantan, Pahang.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Electric apparatus and materials. Electric circuits. Electric networks
spellingShingle Electric apparatus and materials. Electric circuits. Electric networks
Fard, Ali Asghar Fathollahi
Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
description Transformers need to be protected not only from internal short circuits, but also from abnormal operating Conditions, such as over loading, inrush currents, go-through faults and surges. The simplest but extremely effective form of protection is the electromechanical relay, which closes contacts and hence energizes the circuit-breaker opening mechanisms when currents larger than allowed values pass through. In a power system, the differential relay should operate only in its indicated protection zone, and not for out of its protection zone. This paper will focus on the problem, where the differential relay (87) indiscriminately functions for its out of protection zone. Effect of mismatching currents has been considered.
format Conference or Workshop Item
author Fard, Ali Asghar Fathollahi
author_facet Fard, Ali Asghar Fathollahi
author_sort Fard, Ali Asghar Fathollahi
title Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
title_short Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
title_full Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
title_fullStr Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
title_full_unstemmed Effect of mismatching currents on performance of differential relay (87) / Ali Asghar Fathollahi Fard
title_sort effect of mismatching currents on performance of differential relay (87) / ali asghar fathollahi fard
publishDate 2006
url https://ir.uitm.edu.my/id/eprint/81834/1/81834.PDF
https://ir.uitm.edu.my/id/eprint/81834/
_version_ 1781709244817473536