Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers

A multiwavelength Ytterbium-doped fiber ring laser operating at 1030 nm region is demonstrated using a Sagnac loop mirror and a Mach-Zehnder interferometer. We report the Performance comparisons of multi-wavelength oscillations in Yb(3+) doped fiber lasers (YDFL) with typical commercial ytterbium do...

Full description

Saved in:
Bibliographic Details
Main Authors: Moghaddam, M.R.A., Harun, Sulaiman Wadi, Shahi, S., Lim, K.S., Ahmad, Harith
Format: Article
Published: IOP Publishing 2010
Subjects:
Online Access:http://eprints.um.edu.my/15245/
https://doi.org/10.1134/S1054660X10030138
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.15245
record_format eprints
spelling my.um.eprints.152452019-04-08T05:06:09Z http://eprints.um.edu.my/15245/ Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers Moghaddam, M.R.A. Harun, Sulaiman Wadi Shahi, S. Lim, K.S. Ahmad, Harith Q Science (General) A multiwavelength Ytterbium-doped fiber ring laser operating at 1030 nm region is demonstrated using a Sagnac loop mirror and a Mach-Zehnder interferometer. We report the Performance comparisons of multi-wavelength oscillations in Yb(3+) doped fiber lasers (YDFL) with typical commercial ytterbium doped silica fibers. By adjusting the polarization controller (PC), a widely tunable laser range of 22 nm from 1030 nm to 1050 nm is obtained. The Mach-Zehnder interferometer (MZI) design has exhibited simplicity in the operation for controlling the smallest wavelength spacing compared to Sagnac loop mirror method. In our observations, the smallest achieved stable wavelength spacing in Sagnac loop mirror setup and MZI setup were 2.1 nm and 0.7 nm, respectively. In case of nine-wavelength operation with a MZI setup, the stability, Full Width at Half Maximum (FWHM) and side mode suppression ratio (SMSR) of laser lines are not affected by increasing pump power, While for above four wavelength operation, the laser stability with Sagnac loop mirror becomes worse specially for higher input pump power and the power fluctuation among the wave-lengths would be also slightly larger. IOP Publishing 2010 Article PeerReviewed Moghaddam, M.R.A. and Harun, Sulaiman Wadi and Shahi, S. and Lim, K.S. and Ahmad, Harith (2010) Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers. Laser Physics, 20 (2). pp. 516-521. ISSN 1054-660X https://doi.org/10.1134/S1054660X10030138 doi:10.1134/S1054660X10030138
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Moghaddam, M.R.A.
Harun, Sulaiman Wadi
Shahi, S.
Lim, K.S.
Ahmad, Harith
Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
description A multiwavelength Ytterbium-doped fiber ring laser operating at 1030 nm region is demonstrated using a Sagnac loop mirror and a Mach-Zehnder interferometer. We report the Performance comparisons of multi-wavelength oscillations in Yb(3+) doped fiber lasers (YDFL) with typical commercial ytterbium doped silica fibers. By adjusting the polarization controller (PC), a widely tunable laser range of 22 nm from 1030 nm to 1050 nm is obtained. The Mach-Zehnder interferometer (MZI) design has exhibited simplicity in the operation for controlling the smallest wavelength spacing compared to Sagnac loop mirror method. In our observations, the smallest achieved stable wavelength spacing in Sagnac loop mirror setup and MZI setup were 2.1 nm and 0.7 nm, respectively. In case of nine-wavelength operation with a MZI setup, the stability, Full Width at Half Maximum (FWHM) and side mode suppression ratio (SMSR) of laser lines are not affected by increasing pump power, While for above four wavelength operation, the laser stability with Sagnac loop mirror becomes worse specially for higher input pump power and the power fluctuation among the wave-lengths would be also slightly larger.
format Article
author Moghaddam, M.R.A.
Harun, Sulaiman Wadi
Shahi, S.
Lim, K.S.
Ahmad, Harith
author_facet Moghaddam, M.R.A.
Harun, Sulaiman Wadi
Shahi, S.
Lim, K.S.
Ahmad, Harith
author_sort Moghaddam, M.R.A.
title Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
title_short Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
title_full Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
title_fullStr Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
title_full_unstemmed Comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
title_sort comparisons of multi-wavelength oscillations using sagnac loop mirror and mach-zehnder interferometer for ytterbium doped fiber lasers
publisher IOP Publishing
publishDate 2010
url http://eprints.um.edu.my/15245/
https://doi.org/10.1134/S1054660X10030138
_version_ 1643690012015853568