Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate
The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatme...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2017
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/17466/1/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate.pdf http://umpir.ump.edu.my/id/eprint/17466/7/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate%201.pdf http://umpir.ump.edu.my/id/eprint/17466/ http://www.sciencedirect.com/science/article/pii/S2352710216301449 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English English |
id |
my.ump.umpir.17466 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.174662018-02-08T06:38:51Z http://umpir.ump.edu.my/id/eprint/17466/ Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate Azizuddin, Abd Aziz Daisuke, Sumiyoshi Yasunori, Akashi TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50%, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2% compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants. Elsevier Ltd 2017 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/17466/1/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/17466/7/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate%201.pdf Azizuddin, Abd Aziz and Daisuke, Sumiyoshi and Yasunori, Akashi (2017) Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate. Journal of Building Engineering, 11. pp. 9-16. ISSN 2352-7102 http://www.sciencedirect.com/science/article/pii/S2352710216301449 DOI: 10.1016/j.jobe.2017.03.005 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery |
spellingShingle |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Azizuddin, Abd Aziz Daisuke, Sumiyoshi Yasunori, Akashi Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
description |
The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50%, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2% compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants. |
format |
Article |
author |
Azizuddin, Abd Aziz Daisuke, Sumiyoshi Yasunori, Akashi |
author_facet |
Azizuddin, Abd Aziz Daisuke, Sumiyoshi Yasunori, Akashi |
author_sort |
Azizuddin, Abd Aziz |
title |
Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
title_short |
Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
title_full |
Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
title_fullStr |
Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
title_full_unstemmed |
Low Cost Humidity Controlled Air-Conditioning System for Building Energy Savings in Tropical Climate |
title_sort |
low cost humidity controlled air-conditioning system for building energy savings in tropical climate |
publisher |
Elsevier Ltd |
publishDate |
2017 |
url |
http://umpir.ump.edu.my/id/eprint/17466/1/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate.pdf http://umpir.ump.edu.my/id/eprint/17466/7/Low%20cost%20humidity%20controlled%20air-conditioning%20system%20for%20building%20energy%20savings%20in%20tropical%20climate%201.pdf http://umpir.ump.edu.my/id/eprint/17466/ http://www.sciencedirect.com/science/article/pii/S2352710216301449 |
_version_ |
1643668189477863424 |