Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers

Industrial designs have tremendously changed within the last decade, with its time and nonlinear variation loads in power frameworks spectrum expanding widely. This revolution has resulted in increased quality control problems such as current unbalance, current and voltage harmonics, flicker and poo...

Full description

Saved in:
Bibliographic Details
Main Authors: Omran, Mohamed Asghaiyer, Izzeldin, I. Mohd, Almelian, Mohamad Milood, Dawood, Mohammed A., Al-Izzi, M. Y.
Format: Article
Language:English
Published: UTeM 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/20989/1/Shunt%20hybrid%20active%20power%20filter%20based%20on%20two%20compensation.pdf
http://umpir.ump.edu.my/id/eprint/20989/
http://journal.utem.edu.my/index.php/jtec/article/view/3487
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.20989
record_format eprints
spelling my.ump.umpir.209892018-08-17T03:03:15Z http://umpir.ump.edu.my/id/eprint/20989/ Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers Omran, Mohamed Asghaiyer Izzeldin, I. Mohd Almelian, Mohamad Milood Dawood, Mohammed A. Al-Izzi, M. Y. TK Electrical engineering. Electronics Nuclear engineering Industrial designs have tremendously changed within the last decade, with its time and nonlinear variation loads in power frameworks spectrum expanding widely. This revolution has resulted in increased quality control problems such as current unbalance, current and voltage harmonics, flicker and poor power factor in control frameworks. The aim of this paper is to address this problem through the development of Synchronous Reference Frame and Reactive Power (SRF and P-Q) control methods. The DC voltage was regulated to its set reference for providing the current reference using proportional-Integral (PI) and fuzzy logic controllers. From the results, Fuzzy logic control was shown to achieve an adequate DC capacitor energy storage optimization, the sinusoidal type of the current and the change of the power factor. A low Total Harmonic Distortion (THD) that met the suggestions of IEEE- 519 standard on symphonious levels was achieved with the proposed method. UTeM 2018 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/20989/1/Shunt%20hybrid%20active%20power%20filter%20based%20on%20two%20compensation.pdf Omran, Mohamed Asghaiyer and Izzeldin, I. Mohd and Almelian, Mohamad Milood and Dawood, Mohammed A. and Al-Izzi, M. Y. (2018) Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers. Journal of Telecommunication, Electronic and Computer Engineering, 10 (1-3). pp. 75-79. ISSN 2180-1843 (Print); 2289-8131 (Online) http://journal.utem.edu.my/index.php/jtec/article/view/3487
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Almelian, Mohamad Milood
Dawood, Mohammed A.
Al-Izzi, M. Y.
Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
description Industrial designs have tremendously changed within the last decade, with its time and nonlinear variation loads in power frameworks spectrum expanding widely. This revolution has resulted in increased quality control problems such as current unbalance, current and voltage harmonics, flicker and poor power factor in control frameworks. The aim of this paper is to address this problem through the development of Synchronous Reference Frame and Reactive Power (SRF and P-Q) control methods. The DC voltage was regulated to its set reference for providing the current reference using proportional-Integral (PI) and fuzzy logic controllers. From the results, Fuzzy logic control was shown to achieve an adequate DC capacitor energy storage optimization, the sinusoidal type of the current and the change of the power factor. A low Total Harmonic Distortion (THD) that met the suggestions of IEEE- 519 standard on symphonious levels was achieved with the proposed method.
format Article
author Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Almelian, Mohamad Milood
Dawood, Mohammed A.
Al-Izzi, M. Y.
author_facet Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Almelian, Mohamad Milood
Dawood, Mohammed A.
Al-Izzi, M. Y.
author_sort Omran, Mohamed Asghaiyer
title Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
title_short Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
title_full Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
title_fullStr Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
title_full_unstemmed Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers
title_sort shunt hybrid active power filter based on two compensation strategies with pi and fuzzy logic controllers
publisher UTeM
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/20989/1/Shunt%20hybrid%20active%20power%20filter%20based%20on%20two%20compensation.pdf
http://umpir.ump.edu.my/id/eprint/20989/
http://journal.utem.edu.my/index.php/jtec/article/view/3487
_version_ 1643669021779820544