Development of micro EDM with directly mounted APA 400MML actuator
The development of new, advanced engineering materials and the need for precise flexible prototypes and low volume production have made Micro-EDM and important manufacturing process to meet such demands. The most important parameters in Micro-EDM are the material removal rate (MRR), the tool wear ra...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Trans Tech Publications, Switzerland
2011
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/25947/1/Development%20of%20micro%20EDM%20with%20directly%20mounted%20APA%20400MML%20actuator.pdf http://umpir.ump.edu.my/id/eprint/25947/ https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.25947 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.259472019-10-17T00:57:29Z http://umpir.ump.edu.my/id/eprint/25947/ Development of micro EDM with directly mounted APA 400MML actuator Samykano, Mahendran Fazli, Ismail Chander, Sawalingam Thinesh TJ Mechanical engineering and machinery The development of new, advanced engineering materials and the need for precise flexible prototypes and low volume production have made Micro-EDM and important manufacturing process to meet such demands. The most important parameters in Micro-EDM are the material removal rate (MRR), the tool wear rate (TWR), accuracy and surface texture. The influence of peak current, gap voltage, pulse duration and process parameters plays important role in determining the material removal rate and tool wear rate on Micro EDM. Thus, this paper describes the development of the Micro-EDM based on the tool wear rate and material removal rate of the system using directly mounted APA 400MML actuator as the tool feed control system. Trans Tech Publications, Switzerland 2011 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25947/1/Development%20of%20micro%20EDM%20with%20directly%20mounted%20APA%20400MML%20actuator.pdf Samykano, Mahendran and Fazli, Ismail and Chander, Sawalingam Thinesh (2011) Development of micro EDM with directly mounted APA 400MML actuator. Advanced Materials Research, 314-316. pp. 1811-1817. ISSN 1022-6680 (print), 1662-8985 (online) https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Samykano, Mahendran Fazli, Ismail Chander, Sawalingam Thinesh Development of micro EDM with directly mounted APA 400MML actuator |
description |
The development of new, advanced engineering materials and the need for precise flexible prototypes and low volume production have made Micro-EDM and important manufacturing process to meet such demands. The most important parameters in Micro-EDM are the material removal rate (MRR), the tool wear rate (TWR), accuracy and surface texture. The influence of peak current, gap voltage, pulse duration and process parameters plays important role in determining the material removal rate and tool wear rate on Micro EDM. Thus, this paper describes the development of the Micro-EDM based on the tool wear rate and material removal rate of the system using directly mounted APA 400MML actuator as the tool feed control system. |
format |
Article |
author |
Samykano, Mahendran Fazli, Ismail Chander, Sawalingam Thinesh |
author_facet |
Samykano, Mahendran Fazli, Ismail Chander, Sawalingam Thinesh |
author_sort |
Samykano, Mahendran |
title |
Development of micro EDM with directly mounted APA 400MML actuator |
title_short |
Development of micro EDM with directly mounted APA 400MML actuator |
title_full |
Development of micro EDM with directly mounted APA 400MML actuator |
title_fullStr |
Development of micro EDM with directly mounted APA 400MML actuator |
title_full_unstemmed |
Development of micro EDM with directly mounted APA 400MML actuator |
title_sort |
development of micro edm with directly mounted apa 400mml actuator |
publisher |
Trans Tech Publications, Switzerland |
publishDate |
2011 |
url |
http://umpir.ump.edu.my/id/eprint/25947/1/Development%20of%20micro%20EDM%20with%20directly%20mounted%20APA%20400MML%20actuator.pdf http://umpir.ump.edu.my/id/eprint/25947/ https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 https://doi.org/10.4028/www.scientific.net/AMR.314-316.1811 |
_version_ |
1648741227594514432 |