Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation

Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error...

Full description

Saved in:
Bibliographic Details
Main Authors: Nurul Nadia, Mohammad, Mohd Hezri, Marzaki, Ramli, Adnan, Mohd Hezri, Fazalul Rahiman, Saiful Nizam, Tajuddin
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28970/1/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation_FULL.pdf
http://umpir.ump.edu.my/id/eprint/28970/2/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation%20.pdf
http://umpir.ump.edu.my/id/eprint/28970/
https://doi.org/10.1109/CSPA.2017.8064965
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
English
id my.ump.umpir.28970
record_format eprints
spelling my.ump.umpir.289702022-12-29T03:50:00Z http://umpir.ump.edu.my/id/eprint/28970/ Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation Nurul Nadia, Mohammad Mohd Hezri, Marzaki Ramli, Adnan Mohd Hezri, Fazalul Rahiman Saiful Nizam, Tajuddin TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TP Chemical technology Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load to enhance the performance of the system. In this study, a setpoint was set to 80°C and the comparative performance of PID controller with several tuning rules was evaluate and analyse via simulation. The analysis of the performance was depend on settling time, percentage of overshoot and rise time. Moreover, in this study, the average amount of control signal have been evaluated based on several tuning rules by using an integral control signal. The simulation result shows the ISE-Load that completed with minimum percentage of overshoot could result in best temperature control for hydro distillation process. However, in term of energy consumption, PID ZN gives lower energy usage. IEEE 2017-10-10 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/28970/1/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation_FULL.pdf pdf en http://umpir.ump.edu.my/id/eprint/28970/2/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation%20.pdf Nurul Nadia, Mohammad and Mohd Hezri, Marzaki and Ramli, Adnan and Mohd Hezri, Fazalul Rahiman and Saiful Nizam, Tajuddin (2017) Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation. In: IEEE 13th International Colloquium on Signal Processing and its Applications (CSPA 2017), 10 - 12 March 2017 , Parkroyal Penang Resort, Batu Ferringhi Beach, Penang. pp. 275-280. (8064965). ISBN 978-1-5090-1184-1 https://doi.org/10.1109/CSPA.2017.8064965
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TP Chemical technology
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TP Chemical technology
Nurul Nadia, Mohammad
Mohd Hezri, Marzaki
Ramli, Adnan
Mohd Hezri, Fazalul Rahiman
Saiful Nizam, Tajuddin
Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
description Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load to enhance the performance of the system. In this study, a setpoint was set to 80°C and the comparative performance of PID controller with several tuning rules was evaluate and analyse via simulation. The analysis of the performance was depend on settling time, percentage of overshoot and rise time. Moreover, in this study, the average amount of control signal have been evaluated based on several tuning rules by using an integral control signal. The simulation result shows the ISE-Load that completed with minimum percentage of overshoot could result in best temperature control for hydro distillation process. However, in term of energy consumption, PID ZN gives lower energy usage.
format Conference or Workshop Item
author Nurul Nadia, Mohammad
Mohd Hezri, Marzaki
Ramli, Adnan
Mohd Hezri, Fazalul Rahiman
Saiful Nizam, Tajuddin
author_facet Nurul Nadia, Mohammad
Mohd Hezri, Marzaki
Ramli, Adnan
Mohd Hezri, Fazalul Rahiman
Saiful Nizam, Tajuddin
author_sort Nurul Nadia, Mohammad
title Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
title_short Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
title_full Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
title_fullStr Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
title_full_unstemmed Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
title_sort evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation
publisher IEEE
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/28970/1/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation_FULL.pdf
http://umpir.ump.edu.my/id/eprint/28970/2/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation%20.pdf
http://umpir.ump.edu.my/id/eprint/28970/
https://doi.org/10.1109/CSPA.2017.8064965
_version_ 1753788574876041216