Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA

Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. Th...

Full description

Saved in:
Bibliographic Details
Main Authors: Rosli, Danial N., Rasid, Mohd Azri Hizami
Format: Article
Language:English
Published: Penerbit UMP 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf
http://umpir.ump.edu.my/id/eprint/37261/
https://doi.org/10.15282/mekatronika.v4i2.8928
https://doi.org/10.15282/mekatronika.v4i2.8928
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.37261
record_format eprints
spelling my.ump.umpir.372612023-03-10T01:40:36Z http://umpir.ump.edu.my/id/eprint/37261/ Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA Rosli, Danial N. Rasid, Mohd Azri Hizami TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics TS Manufactures Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. This study analyzes the natural frequency and mode shape of major components in 120v 4-Phase 8/6 Pole Switched Reluctance Motor. The material selected are materials that are commonly employed for electrical machines components. It was found that gray cast iron core has the lowest natural frequency for each mode from 1 to 3. This is mainly due to its lower elasticity modulus (10 times smaller in comparison to other materials). Solid and slinky rotor has a very low first mode natural frequency at tens of Hz, which is very susceptible to mechanically induced excitation vibration. Penerbit UMP 2022 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf Rosli, Danial N. and Rasid, Mohd Azri Hizami (2022) Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA. Mekatronika - Journal of Intelligent Manufacturing & Mechatronics, 4 (2). pp. 40-47. ISSN 2637-0883 https://doi.org/10.15282/mekatronika.v4i2.8928 https://doi.org/10.15282/mekatronika.v4i2.8928
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
TS Manufactures
spellingShingle TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
TS Manufactures
Rosli, Danial N.
Rasid, Mohd Azri Hizami
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
description Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. This study analyzes the natural frequency and mode shape of major components in 120v 4-Phase 8/6 Pole Switched Reluctance Motor. The material selected are materials that are commonly employed for electrical machines components. It was found that gray cast iron core has the lowest natural frequency for each mode from 1 to 3. This is mainly due to its lower elasticity modulus (10 times smaller in comparison to other materials). Solid and slinky rotor has a very low first mode natural frequency at tens of Hz, which is very susceptible to mechanically induced excitation vibration.
format Article
author Rosli, Danial N.
Rasid, Mohd Azri Hizami
author_facet Rosli, Danial N.
Rasid, Mohd Azri Hizami
author_sort Rosli, Danial N.
title Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
title_short Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
title_full Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
title_fullStr Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
title_full_unstemmed Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
title_sort modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using fea
publisher Penerbit UMP
publishDate 2022
url http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf
http://umpir.ump.edu.my/id/eprint/37261/
https://doi.org/10.15282/mekatronika.v4i2.8928
https://doi.org/10.15282/mekatronika.v4i2.8928
_version_ 1761616613765808128