Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA
Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. Th...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UMP
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf http://umpir.ump.edu.my/id/eprint/37261/ https://doi.org/10.15282/mekatronika.v4i2.8928 https://doi.org/10.15282/mekatronika.v4i2.8928 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.37261 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.372612023-03-10T01:40:36Z http://umpir.ump.edu.my/id/eprint/37261/ Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA Rosli, Danial N. Rasid, Mohd Azri Hizami TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics TS Manufactures Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. This study analyzes the natural frequency and mode shape of major components in 120v 4-Phase 8/6 Pole Switched Reluctance Motor. The material selected are materials that are commonly employed for electrical machines components. It was found that gray cast iron core has the lowest natural frequency for each mode from 1 to 3. This is mainly due to its lower elasticity modulus (10 times smaller in comparison to other materials). Solid and slinky rotor has a very low first mode natural frequency at tens of Hz, which is very susceptible to mechanically induced excitation vibration. Penerbit UMP 2022 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf Rosli, Danial N. and Rasid, Mohd Azri Hizami (2022) Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA. Mekatronika - Journal of Intelligent Manufacturing & Mechatronics, 4 (2). pp. 40-47. ISSN 2637-0883 https://doi.org/10.15282/mekatronika.v4i2.8928 https://doi.org/10.15282/mekatronika.v4i2.8928 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics TS Manufactures |
spellingShingle |
TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics TS Manufactures Rosli, Danial N. Rasid, Mohd Azri Hizami Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
description |
Vibration causes acoustic nuisance, aggravating fatigue etc. Knowing that resonance is caused by amplified deformation when a structure is excited at natural frequency, modal analysis is important to identify the natural frequency and mode of deformation that may be excited in electrical machine. This study analyzes the natural frequency and mode shape of major components in 120v 4-Phase 8/6 Pole Switched Reluctance Motor. The material selected are materials that are commonly employed for electrical machines components. It was found that gray cast iron core has the lowest natural frequency for each mode from 1 to 3. This is mainly due to its lower elasticity modulus (10 times smaller in comparison to other materials). Solid and slinky rotor has a very low first mode natural frequency at tens of Hz, which is very susceptible to mechanically induced excitation vibration. |
format |
Article |
author |
Rosli, Danial N. Rasid, Mohd Azri Hizami |
author_facet |
Rosli, Danial N. Rasid, Mohd Azri Hizami |
author_sort |
Rosli, Danial N. |
title |
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
title_short |
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
title_full |
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
title_fullStr |
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
title_full_unstemmed |
Modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using FEA |
title_sort |
modal analysis of an 8/6 pole switched reluctance motor core with different materials and assembly method using fea |
publisher |
Penerbit UMP |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/37261/1/Modal%20%20Analysis%20%20of%20%20an%20%208_6%20%20Pole%20%20Switched%20%20Reluctance%20%20Motor%20%20Core.pdf http://umpir.ump.edu.my/id/eprint/37261/ https://doi.org/10.15282/mekatronika.v4i2.8928 https://doi.org/10.15282/mekatronika.v4i2.8928 |
_version_ |
1761616613765808128 |