Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)

A PVC blended lipid membrane coated quartz crystal microbalance has been prepared to mimic human olfaction system. Transient response curves of the sensor on exposure to methanol, ethanol, chloroform, acetone and benzene were studied. Transient parameters, viz., simple parameters consisting of peak...

Full description

Saved in:
Bibliographic Details
Main Authors: Shafiqul Islam, A.K.M., Ismail, Z., Mohd Noor, Ahmad, Saad, B., Othman, A.R., Ali Yeon, Md Shakaff, Daud, A., Ishak, Z.
Format: Article
Language:English
Published: School of Materials Engineering; School of Computer and Communication Engineering 2013
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/30807
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Perlis
Language: English
id my.unimap-30807
record_format dspace
spelling my.unimap-308072013-12-23T09:39:45Z Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs) Shafiqul Islam, A.K.M. Ismail, Z. Mohd Noor, Ahmad Saad, B. Othman, A.R. Ali Yeon, Md Shakaff Daud, A. Ishak, Z. Lipid membrane sensor Volatile organic compounds QCM sensor Transient response A PVC blended lipid membrane coated quartz crystal microbalance has been prepared to mimic human olfaction system. Transient response curves of the sensor on exposure to methanol, ethanol, chloroform, acetone and benzene were studied. Transient parameters, viz., simple parameters consisting of peak heights, derivatives, slopes and integrals, and polynomial parameters consisting of coefficients from the curve fitting equations, were extracted from the transient response curves and used as data for the subsequent chemometric data analysis. The sensor showed good separation and classification of VOCs. © 2005 Elsevier B.V. All rights reserved. 2013-12-23T09:39:45Z 2013-12-23T09:39:45Z 2005-09-30 Article Shafiqul Islam, A.K.M., Ismail, Z., Ahmad, M.N., Saad, B., Othman, A.R., Shakaff, A.Y.Md., Daud, A., Ishak, Z. Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs) 0925-4005 http://hdl.handle.net/123456789/30807 en Sensors and Actuators B;Impact Factor: 2.646 School of Materials Engineering; School of Computer and Communication Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Lipid membrane sensor
Volatile organic compounds
QCM sensor
Transient response
spellingShingle Lipid membrane sensor
Volatile organic compounds
QCM sensor
Transient response
Shafiqul Islam, A.K.M.
Ismail, Z.
Mohd Noor, Ahmad
Saad, B.
Othman, A.R.
Ali Yeon, Md Shakaff
Daud, A.
Ishak, Z.
Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
description A PVC blended lipid membrane coated quartz crystal microbalance has been prepared to mimic human olfaction system. Transient response curves of the sensor on exposure to methanol, ethanol, chloroform, acetone and benzene were studied. Transient parameters, viz., simple parameters consisting of peak heights, derivatives, slopes and integrals, and polynomial parameters consisting of coefficients from the curve fitting equations, were extracted from the transient response curves and used as data for the subsequent chemometric data analysis. The sensor showed good separation and classification of VOCs. © 2005 Elsevier B.V. All rights reserved.
format Article
author Shafiqul Islam, A.K.M.
Ismail, Z.
Mohd Noor, Ahmad
Saad, B.
Othman, A.R.
Ali Yeon, Md Shakaff
Daud, A.
Ishak, Z.
author_facet Shafiqul Islam, A.K.M.
Ismail, Z.
Mohd Noor, Ahmad
Saad, B.
Othman, A.R.
Ali Yeon, Md Shakaff
Daud, A.
Ishak, Z.
author_sort Shafiqul Islam, A.K.M.
title Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
title_short Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
title_full Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
title_fullStr Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
title_full_unstemmed Transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (VOCs)
title_sort transient parameters of a coated quartz crystal microbalance sensor for the detection of volatile organic compounds (vocs)
publisher School of Materials Engineering; School of Computer and Communication Engineering
publishDate 2013
url http://dspace.unimap.edu.my/xmlui/handle/123456789/30807
_version_ 1643796387371941888