Adaptive low-cost home cooling systems

Malaysia's citizen is experiencing thennal discomfort in their homes, particularly low-cost houses because Malaysia experience the equatorial climate with high and unifonn temperature as well as high humidity. So, they are in dire need of cooling system in their home to achieve the level of the...

Full description

Saved in:
Bibliographic Details
Main Author: Chua, Chee Kiong
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak, (UNIMAS) 2012
Subjects:
Online Access:http://ir.unimas.my/id/eprint/12635/1/Adaptive%20low-cost%20home%20cooling%20systems%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/12635/8/Adaptive%20low-cost%20home%20cooling%20systems%20%28fulltext%29.pdf
http://ir.unimas.my/id/eprint/12635/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Sarawak
Language: English
English
id my.unimas.ir.12635
record_format eprints
spelling my.unimas.ir.126352023-02-01T08:07:04Z http://ir.unimas.my/id/eprint/12635/ Adaptive low-cost home cooling systems Chua, Chee Kiong TK Electrical engineering. Electronics Nuclear engineering Malaysia's citizen is experiencing thennal discomfort in their homes, particularly low-cost houses because Malaysia experience the equatorial climate with high and unifonn temperature as well as high humidity. So, they are in dire need of cooling system in their home to achieve the level of thermal comfort. Cooling system which can provide energy savings, the effect of thennal comfort, and low price are preferable. Thus, objective of the study is to develop a suitable cooling system for low-cost house and a system to monitor the temperature and humidity data inside the house. The focus of this study is the implementation of hardware by using sensor circuit, Programmable Integrated Circuit (PIC) circuit as controller system, cooling system, and the implementation of the software for monitoring system. When the thennal discomfort condition occurs in the .ow-cost house, the developed system is able to activate the cooling system technology automatically and it is controlled by a sensor controller circuit and Graphical User Interface program (GUI) that can maintain the thennal comfort condition in the environment of low-cost houses with the air temperature in the range of 26.0 °C to 30.7 °C and relative humidity is always higher than 70.0%. Universiti Malaysia Sarawak, (UNIMAS) 2012 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/12635/1/Adaptive%20low-cost%20home%20cooling%20systems%20%2824pgs%29.pdf text en http://ir.unimas.my/id/eprint/12635/8/Adaptive%20low-cost%20home%20cooling%20systems%20%28fulltext%29.pdf Chua, Chee Kiong (2012) Adaptive low-cost home cooling systems. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chua, Chee Kiong
Adaptive low-cost home cooling systems
description Malaysia's citizen is experiencing thennal discomfort in their homes, particularly low-cost houses because Malaysia experience the equatorial climate with high and unifonn temperature as well as high humidity. So, they are in dire need of cooling system in their home to achieve the level of thermal comfort. Cooling system which can provide energy savings, the effect of thennal comfort, and low price are preferable. Thus, objective of the study is to develop a suitable cooling system for low-cost house and a system to monitor the temperature and humidity data inside the house. The focus of this study is the implementation of hardware by using sensor circuit, Programmable Integrated Circuit (PIC) circuit as controller system, cooling system, and the implementation of the software for monitoring system. When the thennal discomfort condition occurs in the .ow-cost house, the developed system is able to activate the cooling system technology automatically and it is controlled by a sensor controller circuit and Graphical User Interface program (GUI) that can maintain the thennal comfort condition in the environment of low-cost houses with the air temperature in the range of 26.0 °C to 30.7 °C and relative humidity is always higher than 70.0%.
format Final Year Project Report
author Chua, Chee Kiong
author_facet Chua, Chee Kiong
author_sort Chua, Chee Kiong
title Adaptive low-cost home cooling systems
title_short Adaptive low-cost home cooling systems
title_full Adaptive low-cost home cooling systems
title_fullStr Adaptive low-cost home cooling systems
title_full_unstemmed Adaptive low-cost home cooling systems
title_sort adaptive low-cost home cooling systems
publisher Universiti Malaysia Sarawak, (UNIMAS)
publishDate 2012
url http://ir.unimas.my/id/eprint/12635/1/Adaptive%20low-cost%20home%20cooling%20systems%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/12635/8/Adaptive%20low-cost%20home%20cooling%20systems%20%28fulltext%29.pdf
http://ir.unimas.my/id/eprint/12635/
_version_ 1756688289945878528