A Study of Indoor Air Quality in Refurbished Museum Building
Problem related with indoor air quality (IAQ), is rapidly becoming a major health issue as people spend almost 90% of their time indoors. Museums were established in Malaysia more than hundred years ago. Since the year 2005, Malaysia has been moving away from constructing new buildings in favour o...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
CEJ
2018
|
Subjects: | |
Online Access: | http://ir.unimas.my/id/eprint/25615/1/A%20Study%20of%20Indoor%20Air%20Quality%20in%20Refurbished%20Museum%20Building%20%28abstract%29.pdf http://ir.unimas.my/id/eprint/25615/ https://civilejournal.org/index.php/cej/article/view/1026 http://dx.doi.org/10.28991/cej-03091184 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Sarawak |
Language: | English |
id |
my.unimas.ir.25615 |
---|---|
record_format |
eprints |
spelling |
my.unimas.ir.256152023-05-16T01:56:11Z http://ir.unimas.my/id/eprint/25615/ A Study of Indoor Air Quality in Refurbished Museum Building Syahrun Neizam, Mohd Dzulkifli Abd Halid, Abdullah Lee, Yee Yong Abdul Mutalib, Leman Samiullah, Sohu TC Hydraulic engineering. Ocean engineering Problem related with indoor air quality (IAQ), is rapidly becoming a major health issue as people spend almost 90% of their time indoors. Museums were established in Malaysia more than hundred years ago. Since the year 2005, Malaysia has been moving away from constructing new buildings in favour of refurbishing historic and old ones. A healthy environment at the museum building has been identified as one of the important element that must been considered, but it is not sure either IAQ in the museum building provide a good air quality or not. The purpose of this study is to determine the actual indoor environment of the museum building in Melaka. In this study, the IAQ measurement were conduct for six days at the Melaka Sultanate Palace Museum and at the History and Ethnography Museum. During the measurement, IAQ parameters of gaseous pollutant of nitrogen dioxide, sulfur dioxide and carbon dioxide, and particulate matter of fine particles were recorded by using specific IAQ equipment. The finding of this study indicates that the distance of buildings from roadways appears to have an impact on indoor environmental levels, especially for nitrogen dioxide, sulfur dioxide and particulate matter. Based on the results, only gaseous pollutant of sulfur dioxide had not exceeding the acceptable TLV compared to the other IAQ pollutants. CEJ 2018 Article PeerReviewed text en http://ir.unimas.my/id/eprint/25615/1/A%20Study%20of%20Indoor%20Air%20Quality%20in%20Refurbished%20Museum%20Building%20%28abstract%29.pdf Syahrun Neizam, Mohd Dzulkifli and Abd Halid, Abdullah and Lee, Yee Yong and Abdul Mutalib, Leman and Samiullah, Sohu (2018) A Study of Indoor Air Quality in Refurbished Museum Building. Civil Engineering Journal, 4 (11). pp. 2596-2605. ISSN 2476-3055 https://civilejournal.org/index.php/cej/article/view/1026 http://dx.doi.org/10.28991/cej-03091184 |
institution |
Universiti Malaysia Sarawak |
building |
Centre for Academic Information Services (CAIS) |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sarawak |
content_source |
UNIMAS Institutional Repository |
url_provider |
http://ir.unimas.my/ |
language |
English |
topic |
TC Hydraulic engineering. Ocean engineering |
spellingShingle |
TC Hydraulic engineering. Ocean engineering Syahrun Neizam, Mohd Dzulkifli Abd Halid, Abdullah Lee, Yee Yong Abdul Mutalib, Leman Samiullah, Sohu A Study of Indoor Air Quality in Refurbished Museum Building |
description |
Problem related with indoor air quality (IAQ), is rapidly becoming a major health issue as people spend almost 90% of
their time indoors. Museums were established in Malaysia more than hundred years ago. Since the year 2005, Malaysia
has been moving away from constructing new buildings in favour of refurbishing historic and old ones. A healthy
environment at the museum building has been identified as one of the important element that must been considered, but it is not sure either IAQ in the museum building provide a good air quality or not. The purpose of this study is to determine the actual indoor environment of the museum building in Melaka. In this study, the IAQ measurement were conduct for six days at the Melaka Sultanate Palace Museum and at the History and Ethnography Museum. During the measurement, IAQ parameters of gaseous pollutant of nitrogen dioxide, sulfur dioxide and carbon dioxide, and particulate matter of fine particles were recorded by using specific IAQ equipment. The finding of this study indicates that the distance of buildings from roadways appears to have an impact on indoor environmental levels, especially for nitrogen dioxide, sulfur dioxide and particulate matter. Based on the results, only gaseous pollutant of sulfur dioxide had not exceeding the acceptable TLV
compared to the other IAQ pollutants. |
format |
Article |
author |
Syahrun Neizam, Mohd Dzulkifli Abd Halid, Abdullah Lee, Yee Yong Abdul Mutalib, Leman Samiullah, Sohu |
author_facet |
Syahrun Neizam, Mohd Dzulkifli Abd Halid, Abdullah Lee, Yee Yong Abdul Mutalib, Leman Samiullah, Sohu |
author_sort |
Syahrun Neizam, Mohd Dzulkifli |
title |
A Study of Indoor Air Quality in Refurbished Museum Building |
title_short |
A Study of Indoor Air Quality in Refurbished Museum Building |
title_full |
A Study of Indoor Air Quality in Refurbished Museum Building |
title_fullStr |
A Study of Indoor Air Quality in Refurbished Museum Building |
title_full_unstemmed |
A Study of Indoor Air Quality in Refurbished Museum Building |
title_sort |
study of indoor air quality in refurbished museum building |
publisher |
CEJ |
publishDate |
2018 |
url |
http://ir.unimas.my/id/eprint/25615/1/A%20Study%20of%20Indoor%20Air%20Quality%20in%20Refurbished%20Museum%20Building%20%28abstract%29.pdf http://ir.unimas.my/id/eprint/25615/ https://civilejournal.org/index.php/cej/article/view/1026 http://dx.doi.org/10.28991/cej-03091184 |
_version_ |
1767209834532306944 |