Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables

The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments...

Full description

Saved in:
Bibliographic Details
Main Authors: Avinash A.R., Chakrabarty C.K., Permal N., Agileswari
Other Authors: 56781356900
Format: Article
Published: Asian Research Publishing Network 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-22726
record_format dspace
spelling my.uniten.dspace-227262023-05-29T14:11:51Z Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables Avinash A.R. Chakrabarty C.K. Permal N. Agileswari 56781356900 6701755282 56781496300 16023154400 The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments are that the experimental setup is shrunk and special resolutions are improved. This method can measure as short as 1 meter HV cable's. This method was calibrated using cables manufactured with imperfections to distinguish various severities and also with a good cable as benchmark. A calibration curve was established by correlating the HFAC tangent delta measurement system's results with a 50 Hz marketed measurement system. The HFAC method is then used to measure actual field samples taken 20 meters away from a breakdown. Failure Analysis and HFAC result corresponds with the insulation measured being aged. � 2006-2016 Asian Research Publishing Network (ARPN). Final 2023-05-29T06:11:51Z 2023-05-29T06:11:51Z 2016 Article 2-s2.0-84971474835 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971474835&partnerID=40&md5=e889c1b689f92691528f3086dce34e07 https://irepository.uniten.edu.my/handle/123456789/22726 11 10 6284 6289 Asian Research Publishing Network Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments are that the experimental setup is shrunk and special resolutions are improved. This method can measure as short as 1 meter HV cable's. This method was calibrated using cables manufactured with imperfections to distinguish various severities and also with a good cable as benchmark. A calibration curve was established by correlating the HFAC tangent delta measurement system's results with a 50 Hz marketed measurement system. The HFAC method is then used to measure actual field samples taken 20 meters away from a breakdown. Failure Analysis and HFAC result corresponds with the insulation measured being aged. � 2006-2016 Asian Research Publishing Network (ARPN).
author2 56781356900
author_facet 56781356900
Avinash A.R.
Chakrabarty C.K.
Permal N.
Agileswari
format Article
author Avinash A.R.
Chakrabarty C.K.
Permal N.
Agileswari
spellingShingle Avinash A.R.
Chakrabarty C.K.
Permal N.
Agileswari
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
author_sort Avinash A.R.
title Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
title_short Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
title_full Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
title_fullStr Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
title_full_unstemmed Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
title_sort tangent delta low voltage high frequency ac method to measure hv underground xlpe cables
publisher Asian Research Publishing Network
publishDate 2023
_version_ 1806426380460621824