Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables
The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Asian Research Publishing Network
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-22726 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-227262023-05-29T14:11:51Z Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables Avinash A.R. Chakrabarty C.K. Permal N. Agileswari 56781356900 6701755282 56781496300 16023154400 The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments are that the experimental setup is shrunk and special resolutions are improved. This method can measure as short as 1 meter HV cable's. This method was calibrated using cables manufactured with imperfections to distinguish various severities and also with a good cable as benchmark. A calibration curve was established by correlating the HFAC tangent delta measurement system's results with a 50 Hz marketed measurement system. The HFAC method is then used to measure actual field samples taken 20 meters away from a breakdown. Failure Analysis and HFAC result corresponds with the insulation measured being aged. � 2006-2016 Asian Research Publishing Network (ARPN). Final 2023-05-29T06:11:51Z 2023-05-29T06:11:51Z 2016 Article 2-s2.0-84971474835 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971474835&partnerID=40&md5=e889c1b689f92691528f3086dce34e07 https://irepository.uniten.edu.my/handle/123456789/22726 11 10 6284 6289 Asian Research Publishing Network Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
The Tangent Delta utilizing Low Voltage High Frequency Alternating Current is a method to test cables insulation durability. Phase shifts between the current and voltage across the cable are utilized to obtain the Tangent delta measurement. Advantages of this method compared to the market equipments are that the experimental setup is shrunk and special resolutions are improved. This method can measure as short as 1 meter HV cable's. This method was calibrated using cables manufactured with imperfections to distinguish various severities and also with a good cable as benchmark. A calibration curve was established by correlating the HFAC tangent delta measurement system's results with a 50 Hz marketed measurement system. The HFAC method is then used to measure actual field samples taken 20 meters away from a breakdown. Failure Analysis and HFAC result corresponds with the insulation measured being aged. � 2006-2016 Asian Research Publishing Network (ARPN). |
author2 |
56781356900 |
author_facet |
56781356900 Avinash A.R. Chakrabarty C.K. Permal N. Agileswari |
format |
Article |
author |
Avinash A.R. Chakrabarty C.K. Permal N. Agileswari |
spellingShingle |
Avinash A.R. Chakrabarty C.K. Permal N. Agileswari Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
author_sort |
Avinash A.R. |
title |
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
title_short |
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
title_full |
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
title_fullStr |
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
title_full_unstemmed |
Tangent delta low voltage high frequency ac method to measure HV underground XLPE cables |
title_sort |
tangent delta low voltage high frequency ac method to measure hv underground xlpe cables |
publisher |
Asian Research Publishing Network |
publishDate |
2023 |
_version_ |
1806426380460621824 |