Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements

The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried ou...

Full description

Saved in:
Bibliographic Details
Main Authors: Rahman N.A., Hussain H., Said I., Jalal T.S., Farag A.S.
Other Authors: 9338388000
Format: Conference paper
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-29803
record_format dspace
spelling my.uniten.dspace-298032023-12-28T16:57:43Z Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements Rahman N.A. Hussain H. Said I. Jalal T.S. Farag A.S. 9338388000 35607922800 56186718000 16022044400 57208098840 Computer simulation Electric industry Electric shielding Magnetic fields Mathematical models Phase measurement Active shielding Double circuit transmission lines Electric power facilities Scaled down models Electric lines The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented. � 2005 IEEE. Final 2023-12-28T08:57:43Z 2023-12-28T08:57:43Z 2005 Conference paper 10.1109/APACE.2005.1607795 2-s2.0-33847330774 https://www.scopus.com/inward/record.uri?eid=2-s2.0-33847330774&doi=10.1109%2fAPACE.2005.1607795&partnerID=40&md5=32e5e6b9a50983f6ce50ab6f63d4bd58 https://irepository.uniten.edu.my/handle/123456789/29803 2005 1607795 147 151 Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Computer simulation
Electric industry
Electric shielding
Magnetic fields
Mathematical models
Phase measurement
Active shielding
Double circuit transmission lines
Electric power facilities
Scaled down models
Electric lines
spellingShingle Computer simulation
Electric industry
Electric shielding
Magnetic fields
Mathematical models
Phase measurement
Active shielding
Double circuit transmission lines
Electric power facilities
Scaled down models
Electric lines
Rahman N.A.
Hussain H.
Said I.
Jalal T.S.
Farag A.S.
Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
description The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented. � 2005 IEEE.
author2 9338388000
author_facet 9338388000
Rahman N.A.
Hussain H.
Said I.
Jalal T.S.
Farag A.S.
format Conference paper
author Rahman N.A.
Hussain H.
Said I.
Jalal T.S.
Farag A.S.
author_sort Rahman N.A.
title Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
title_short Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
title_full Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
title_fullStr Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
title_full_unstemmed Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
title_sort magnetic fields from a scaled down model transmission line - simulation and comparison to measurements
publishDate 2023
_version_ 1806425519528345600