Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models
This paper presents a stochastic aggregate harmonic load (AHL) model built from physical load parameters. Parameters used include nonlinear load composition, diversity factors, and nonlinear load participation in total demand. They are obtained from samples of customer load database of different sec...
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-29852 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-298522023-12-28T16:57:57Z Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models Au M.T. Milanovi? J.V. 9742020600 35508147600 Distribution network Harmonics Stochastic aggregate harmonic load model Computer simulation Electric loads Harmonic distortion Stochastic models Aggregate harmonic load Voltage distortion Electric power distribution This paper presents a stochastic aggregate harmonic load (AHL) model built from physical load parameters. Parameters used include nonlinear load composition, diversity factors, and nonlinear load participation in total demand. They are obtained from samples of customer load database of different sectors of customers. The aggregate load modules are developed for harmonic simulation of distribution network using commercially available software. Uncertainties in loading conditions, load composition and aggregate harmonic load parameters are taken into account separately and simultaneously to determine voltage harmonic distortion levels in distribution network. The simulations performed on a large, realistic distribution network using developed AHL modules give realistic voltage distortion levels/ranges. The results of simulations are in agreement with field measurement results. � 2007 IEEE. Final 2023-12-28T08:57:57Z 2023-12-28T08:57:57Z 2007 Article 10.1109/TPWRD.2007.893193 2-s2.0-34147121575 https://www.scopus.com/inward/record.uri?eid=2-s2.0-34147121575&doi=10.1109%2fTPWRD.2007.893193&partnerID=40&md5=0f4fe9027414008450e67d46e5198dd2 https://irepository.uniten.edu.my/handle/123456789/29852 22 2 1086 1092 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Distribution network Harmonics Stochastic aggregate harmonic load model Computer simulation Electric loads Harmonic distortion Stochastic models Aggregate harmonic load Voltage distortion Electric power distribution |
spellingShingle |
Distribution network Harmonics Stochastic aggregate harmonic load model Computer simulation Electric loads Harmonic distortion Stochastic models Aggregate harmonic load Voltage distortion Electric power distribution Au M.T. Milanovi? J.V. Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
description |
This paper presents a stochastic aggregate harmonic load (AHL) model built from physical load parameters. Parameters used include nonlinear load composition, diversity factors, and nonlinear load participation in total demand. They are obtained from samples of customer load database of different sectors of customers. The aggregate load modules are developed for harmonic simulation of distribution network using commercially available software. Uncertainties in loading conditions, load composition and aggregate harmonic load parameters are taken into account separately and simultaneously to determine voltage harmonic distortion levels in distribution network. The simulations performed on a large, realistic distribution network using developed AHL modules give realistic voltage distortion levels/ranges. The results of simulations are in agreement with field measurement results. � 2007 IEEE. |
author2 |
9742020600 |
author_facet |
9742020600 Au M.T. Milanovi? J.V. |
format |
Article |
author |
Au M.T. Milanovi? J.V. |
author_sort |
Au M.T. |
title |
Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
title_short |
Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
title_full |
Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
title_fullStr |
Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
title_full_unstemmed |
Establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
title_sort |
establishing harmonic distortion level of distribution network based on stochastic aggregate harmonic load models |
publishDate |
2023 |
_version_ |
1806426719253430272 |