The basics and issues of Thermochromic Liquid Crystal Calibrations
Thermochromic Liquid Crystals (TLCs) have been widely used by researchers in heat transfer and fluid flow communities as a thermal imaging tool for mapping surface and spatial temperature distributions. In order to utilize TLCs for quantitative temperature measurements, calibration is first necessar...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2010
|
Online Access: | http://psasir.upm.edu.my/id/eprint/17023/1/The%20basics%20and%20issues%20of%20Thermochromic%20Liquid%20Crystal%20Calibrations.pdf http://psasir.upm.edu.my/id/eprint/17023/ https://www.sciencedirect.com/science/article/pii/S0894177710000683?via%3Dihub#! |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.17023 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.170232019-12-17T06:33:32Z http://psasir.upm.edu.my/id/eprint/17023/ The basics and issues of Thermochromic Liquid Crystal Calibrations Abdullah, Nadia Abu Talib, Abd. Rahim Jaafar, Abdul Aziz Mohd Salleh, Mohamad Amran Chong, Wen Tong Thermochromic Liquid Crystals (TLCs) have been widely used by researchers in heat transfer and fluid flow communities as a thermal imaging tool for mapping surface and spatial temperature distributions. In order to utilize TLCs for quantitative temperature measurements, calibration is first necessary to determine the colour–temperature relationship of TLCs. This paper is aimed to provide novice and intermediate users of TLCs with a review on the basics and issues pertaining to calibrations of TLCs, particularly for surface thermography. A general overview of TLCs, the basic elements of a TLC calibration rig, and the common calibration methods of TLCs are described. The crucial issues associated with calibrations of TLCs, namely, imaging, colourimetry, illumination, hysteresis, film thickness and aging, and the methods used to compensate for these effects are discussed. This paper is intended to provide useful information to novice and intermediate users of TLCs, particularly on TLC calibrations. Elsevier 2010 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/17023/1/The%20basics%20and%20issues%20of%20Thermochromic%20Liquid%20Crystal%20Calibrations.pdf Abdullah, Nadia and Abu Talib, Abd. Rahim and Jaafar, Abdul Aziz and Mohd Salleh, Mohamad Amran and Chong, Wen Tong (2010) The basics and issues of Thermochromic Liquid Crystal Calibrations. Experimental Thermal and Fluid Science, 34 (8). pp. 1089-1121. ISSN 0894-1777; ESSN: 1879-2286 https://www.sciencedirect.com/science/article/pii/S0894177710000683?via%3Dihub#! 10.1016/j.expthermflusci.2010.03.011 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Thermochromic Liquid Crystals (TLCs) have been widely used by researchers in heat transfer and fluid flow communities as a thermal imaging tool for mapping surface and spatial temperature distributions. In order to utilize TLCs for quantitative temperature measurements, calibration is first necessary to determine the colour–temperature relationship of TLCs. This paper is aimed to provide novice and intermediate users of TLCs with a review on the basics and issues pertaining to calibrations of TLCs, particularly for surface thermography. A general overview of TLCs, the basic elements of a TLC calibration rig, and the common calibration methods of TLCs are described. The crucial issues associated with calibrations of TLCs, namely, imaging, colourimetry, illumination, hysteresis, film thickness and aging, and the methods used to compensate for these effects are discussed. This paper is intended to provide useful information to novice and intermediate users of TLCs, particularly on TLC calibrations. |
format |
Article |
author |
Abdullah, Nadia Abu Talib, Abd. Rahim Jaafar, Abdul Aziz Mohd Salleh, Mohamad Amran Chong, Wen Tong |
spellingShingle |
Abdullah, Nadia Abu Talib, Abd. Rahim Jaafar, Abdul Aziz Mohd Salleh, Mohamad Amran Chong, Wen Tong The basics and issues of Thermochromic Liquid Crystal Calibrations |
author_facet |
Abdullah, Nadia Abu Talib, Abd. Rahim Jaafar, Abdul Aziz Mohd Salleh, Mohamad Amran Chong, Wen Tong |
author_sort |
Abdullah, Nadia |
title |
The basics and issues of Thermochromic Liquid Crystal Calibrations |
title_short |
The basics and issues of Thermochromic Liquid Crystal Calibrations |
title_full |
The basics and issues of Thermochromic Liquid Crystal Calibrations |
title_fullStr |
The basics and issues of Thermochromic Liquid Crystal Calibrations |
title_full_unstemmed |
The basics and issues of Thermochromic Liquid Crystal Calibrations |
title_sort |
basics and issues of thermochromic liquid crystal calibrations |
publisher |
Elsevier |
publishDate |
2010 |
url |
http://psasir.upm.edu.my/id/eprint/17023/1/The%20basics%20and%20issues%20of%20Thermochromic%20Liquid%20Crystal%20Calibrations.pdf http://psasir.upm.edu.my/id/eprint/17023/ https://www.sciencedirect.com/science/article/pii/S0894177710000683?via%3Dihub#! |
_version_ |
1654961573193580544 |