Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method.
In the conventional steel fiber reinforced concrete, the structure is fabricated by combining steel fiber to the concrete mix. By using this method, the volume fraction of fiber is limited. So in order to improve the properties of fiber reinforced concrete, slurry infiltrated fiber concrete was intr...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English English English |
Published: |
2013
|
Online Access: | http://psasir.upm.edu.my/id/eprint/28570/1/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf http://psasir.upm.edu.my/id/eprint/28570/2/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf http://psasir.upm.edu.my/id/eprint/28570/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English English English |
id |
my.upm.eprints.28570 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.285702015-09-10T07:52:32Z http://psasir.upm.edu.my/id/eprint/28570/ Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. Abd. Aziz, Farah Nora Aznieta Abdul Rahim, Mustaqqim Md Ghazaly, Zuhayr Shahidan, Shahiron Mohamad Ibrahim, Norlia In the conventional steel fiber reinforced concrete, the structure is fabricated by combining steel fiber to the concrete mix. By using this method, the volume fraction of fiber is limited. So in order to improve the properties of fiber reinforced concrete, slurry infiltrated fiber concrete was introduced. In this study, concrete slurry grades 80 is 3%, 4%, 5% and also the control sample without fiber. Sizes of prism used in this study are 100 x 100 x 500 mm. In order to determine the effect of the curing method, each sample with different volume friction were prepared for two types of curing method. Water curing and steam curing at temperatures of 80° Celsius and cured for 24 hours were applied. The prisms were tested by two-point load test until failure. The behaviors of the prisms were observed and the load-deflection was recorded. Based on the result, it was concluded that the optimum steel fiber content in this report was 5 % by volume friction which provided the highest flexural strength and deflection. The prisms with steam curing obtained lower flexural strength compared to the water curing prisms except for the control specimen. 2013 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28570/1/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf application/pdf en http://psasir.upm.edu.my/id/eprint/28570/2/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf Abd. Aziz, Farah Nora Aznieta and Abdul Rahim, Mustaqqim and Md Ghazaly, Zuhayr and Shahidan, Shahiron and Mohamad Ibrahim, Norlia (2013) Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. Australian Journal of Basic and Applied Sciences, 7 (4). pp. 184-188. ISSN 1991-8178 English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English English |
description |
In the conventional steel fiber reinforced concrete, the structure is fabricated by combining steel fiber to the concrete mix. By using this method, the volume fraction of fiber is limited. So in order to improve the properties of fiber reinforced concrete, slurry infiltrated fiber concrete was introduced. In this study, concrete slurry grades 80 is 3%, 4%, 5% and also the control sample without fiber. Sizes of prism used in this study are 100 x 100 x 500 mm. In order to determine the effect of the curing method, each sample with different volume friction were prepared for two types of curing method. Water curing and steam curing at temperatures of 80° Celsius and cured for 24 hours were applied. The prisms were tested by two-point load test until failure. The behaviors of the prisms were observed and the load-deflection was recorded. Based on the result, it was concluded that the optimum steel fiber content in this report was 5 % by volume friction which provided the highest flexural strength and deflection. The prisms with steam curing obtained lower flexural strength compared to the water curing prisms except for the control specimen. |
format |
Article |
author |
Abd. Aziz, Farah Nora Aznieta Abdul Rahim, Mustaqqim Md Ghazaly, Zuhayr Shahidan, Shahiron Mohamad Ibrahim, Norlia |
spellingShingle |
Abd. Aziz, Farah Nora Aznieta Abdul Rahim, Mustaqqim Md Ghazaly, Zuhayr Shahidan, Shahiron Mohamad Ibrahim, Norlia Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
author_facet |
Abd. Aziz, Farah Nora Aznieta Abdul Rahim, Mustaqqim Md Ghazaly, Zuhayr Shahidan, Shahiron Mohamad Ibrahim, Norlia |
author_sort |
Abd. Aziz, Farah Nora Aznieta |
title |
Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
title_short |
Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
title_full |
Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
title_fullStr |
Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
title_full_unstemmed |
Flexural Behaviour Of High Performance Slurry Infiltrated Fiber Reinforced Concerete With Different Curing Method. |
title_sort |
flexural behaviour of high performance slurry infiltrated fiber reinforced concerete with different curing method. |
publishDate |
2013 |
url |
http://psasir.upm.edu.my/id/eprint/28570/1/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf http://psasir.upm.edu.my/id/eprint/28570/2/Flexural%20Behaviour%20Of%20High%20Performance%20Slurry%20Infiltrated%20Fiber%20Reinforced%20Concerete%20With%20Different%20Curing%20Method.pdf http://psasir.upm.edu.my/id/eprint/28570/ |
_version_ |
1643829504356909056 |