Construction and use of a custom-made digital pressure threshold device in cats

A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure thr...

Full description

Saved in:
Bibliographic Details
Main Authors: Basiri, Bita, Chen, Hee Chong, Dehzangi, Arash
Format: Conference or Workshop Item
Language:English
Published: 2012
Online Access:http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf
http://psasir.upm.edu.my/id/eprint/32215/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.32215
record_format eprints
spelling my.upm.eprints.322152017-01-09T08:39:09Z http://psasir.upm.edu.my/id/eprint/32215/ Construction and use of a custom-made digital pressure threshold device in cats Basiri, Bita Chen, Hee Chong Dehzangi, Arash A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting. 2012 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf Basiri, Bita and Chen, Hee Chong and Dehzangi, Arash (2012) Construction and use of a custom-made digital pressure threshold device in cats. In: International Conference on One Health and 24th VAM Congress 2012, 21-23 Sept. 2012, Marriott Putrajaya. (pp. 177-179).
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting.
format Conference or Workshop Item
author Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
spellingShingle Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
Construction and use of a custom-made digital pressure threshold device in cats
author_facet Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
author_sort Basiri, Bita
title Construction and use of a custom-made digital pressure threshold device in cats
title_short Construction and use of a custom-made digital pressure threshold device in cats
title_full Construction and use of a custom-made digital pressure threshold device in cats
title_fullStr Construction and use of a custom-made digital pressure threshold device in cats
title_full_unstemmed Construction and use of a custom-made digital pressure threshold device in cats
title_sort construction and use of a custom-made digital pressure threshold device in cats
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf
http://psasir.upm.edu.my/id/eprint/32215/
_version_ 1643830543602679808