Construction and use of a custom-made digital pressure threshold device in cats
A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure thr...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2012
|
Online Access: | http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf http://psasir.upm.edu.my/id/eprint/32215/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.32215 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.322152017-01-09T08:39:09Z http://psasir.upm.edu.my/id/eprint/32215/ Construction and use of a custom-made digital pressure threshold device in cats Basiri, Bita Chen, Hee Chong Dehzangi, Arash A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting. 2012 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf Basiri, Bita and Chen, Hee Chong and Dehzangi, Arash (2012) Construction and use of a custom-made digital pressure threshold device in cats. In: International Conference on One Health and 24th VAM Congress 2012, 21-23 Sept. 2012, Marriott Putrajaya. (pp. 177-179). |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR),
connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial
demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting. |
format |
Conference or Workshop Item |
author |
Basiri, Bita Chen, Hee Chong Dehzangi, Arash |
spellingShingle |
Basiri, Bita Chen, Hee Chong Dehzangi, Arash Construction and use of a custom-made digital pressure threshold device in cats |
author_facet |
Basiri, Bita Chen, Hee Chong Dehzangi, Arash |
author_sort |
Basiri, Bita |
title |
Construction and use of a custom-made digital pressure threshold device in cats |
title_short |
Construction and use of a custom-made digital pressure threshold device in cats |
title_full |
Construction and use of a custom-made digital pressure threshold device in cats |
title_fullStr |
Construction and use of a custom-made digital pressure threshold device in cats |
title_full_unstemmed |
Construction and use of a custom-made digital pressure threshold device in cats |
title_sort |
construction and use of a custom-made digital pressure threshold device in cats |
publishDate |
2012 |
url |
http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf http://psasir.upm.edu.my/id/eprint/32215/ |
_version_ |
1643830543602679808 |