Low cost and wearable multichannel surface electromyography data acquisition system architecture
Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
School of Engineering, Taylor’s University College
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf http://psasir.upm.edu.my/id/eprint/34401/ http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.34401 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.344012016-09-15T07:13:21Z http://psasir.upm.edu.my/id/eprint/34401/ Low cost and wearable multichannel surface electromyography data acquisition system architecture Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial single or multichannel surface electromyogram data acquisition system is very expensive for beginner researcher. Some of the systems are available in bulky device, heavy and not portable. As electromyogram detected once muscle is active and contract, a wearable device is desired since several movement will involve during measurement is taken. Therefore, this paper presents architecture of low cost and wearable multichannel surface electromyogram data acquisition system. It is light weight, low power consumption and using stacking system as numbers of electromyography channels used can be varied based on application. School of Engineering, Taylor’s University College 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf Jamaluddin, Nurul Fauzani and Ahmad, Siti Anom and Mohd Noor, Samsul Bahari and Wan Hasan, Wan Zuha (2014) Low cost and wearable multichannel surface electromyography data acquisition system architecture. Journal of Engineering Science and Technology, 9. pp. 98-106. ISSN 1823-4690 http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial single or multichannel surface electromyogram data acquisition system is very expensive for beginner researcher. Some of the systems are available in bulky device, heavy and not portable. As electromyogram detected once muscle is active and contract, a wearable device is desired since several movement will involve during measurement is taken. Therefore, this paper presents architecture of low cost and wearable multichannel surface electromyogram data acquisition system. It is light weight, low power consumption and using stacking system as numbers of electromyography channels used can be varied based on application. |
format |
Article |
author |
Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha |
spellingShingle |
Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha Low cost and wearable multichannel surface electromyography data acquisition system architecture |
author_facet |
Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha |
author_sort |
Jamaluddin, Nurul Fauzani |
title |
Low cost and wearable multichannel surface electromyography data acquisition system architecture |
title_short |
Low cost and wearable multichannel surface electromyography data acquisition system architecture |
title_full |
Low cost and wearable multichannel surface electromyography data acquisition system architecture |
title_fullStr |
Low cost and wearable multichannel surface electromyography data acquisition system architecture |
title_full_unstemmed |
Low cost and wearable multichannel surface electromyography data acquisition system architecture |
title_sort |
low cost and wearable multichannel surface electromyography data acquisition system architecture |
publisher |
School of Engineering, Taylor’s University College |
publishDate |
2014 |
url |
http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf http://psasir.upm.edu.my/id/eprint/34401/ http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
_version_ |
1643831143194165248 |