Shunt active power filter: a review on phase synchronization control techniques
Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic cur...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI
2019
|
Online Access: | http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf http://psasir.upm.edu.my/id/eprint/38327/ https://www.mdpi.com/2079-9292/8/7/791 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.38327 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.383272020-05-04T16:17:45Z http://psasir.upm.edu.my/id/eprint/38327/ Shunt active power filter: a review on phase synchronization control techniques Hoon, Yap Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Md Zawawi, Mohamad Adzhar Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic currents that are present in a harmonic-contaminated power system, and subsequently generates and injects corrective mitigation current back into the power system to cancel out all the detected harmonic currents. This means that other than the ability to generate corrective mitigation current itself, it is actually more important to make sure that the SAPF is able to operate in phase with the operating power system, so that the mitigation current can correctly be injected. Hence, proper synchronization technique needs to be integrated when designing the control algorithms of SAPF. This paper critically discusses and analyzes various types of existing phase synchronization techniques which have been applied to manage operation of SAPF; in terms of features, working principle, implementation and performance. The analysis provided can potentially serve as a guideline and provision of information on selecting the most suitable technique for synchronizing SAPF with the connected power system. MDPI 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf Hoon, Yap and Mohd Radzi, Mohd Amran and Mohd Zainuri, Muhammad Ammirrul Atiqi and Md Zawawi, Mohamad Adzhar (2019) Shunt active power filter: a review on phase synchronization control techniques. Electronics, 8 (7). art. no. 791. pp. 1-20. ISSN 2079-9292 https://www.mdpi.com/2079-9292/8/7/791 10.3390/electronics8070791 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic currents that are present in a harmonic-contaminated power system, and subsequently generates and injects corrective mitigation current back into the power system to cancel out all the detected harmonic currents. This means that other than the ability to generate corrective mitigation current itself, it is actually more important to make sure that the SAPF is able to operate in phase with the operating power system, so that the mitigation current can correctly be injected. Hence, proper synchronization technique needs to be integrated when designing the control algorithms of SAPF. This paper critically discusses and analyzes various types of existing phase synchronization techniques which have been applied to manage operation of SAPF; in terms of features, working principle, implementation and performance. The analysis provided can potentially serve as a guideline and provision of information on selecting the most suitable technique for synchronizing SAPF with the connected power system. |
format |
Article |
author |
Hoon, Yap Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Md Zawawi, Mohamad Adzhar |
spellingShingle |
Hoon, Yap Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Md Zawawi, Mohamad Adzhar Shunt active power filter: a review on phase synchronization control techniques |
author_facet |
Hoon, Yap Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Md Zawawi, Mohamad Adzhar |
author_sort |
Hoon, Yap |
title |
Shunt active power filter: a review on phase synchronization control techniques |
title_short |
Shunt active power filter: a review on phase synchronization control techniques |
title_full |
Shunt active power filter: a review on phase synchronization control techniques |
title_fullStr |
Shunt active power filter: a review on phase synchronization control techniques |
title_full_unstemmed |
Shunt active power filter: a review on phase synchronization control techniques |
title_sort |
shunt active power filter: a review on phase synchronization control techniques |
publisher |
MDPI |
publishDate |
2019 |
url |
http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf http://psasir.upm.edu.my/id/eprint/38327/ https://www.mdpi.com/2079-9292/8/7/791 |
_version_ |
1665895975618609152 |