Flexible bio-signals channels acquisition system for ECG and EMG application

Each nerves and muscles of human body will generate potentials, voltages, and electrical field strength and known as bio signals such as electrocardiograph (ECG), electromyography (EMG), electroencephalogram (EEG), and electrooculogram (EOG). The signals may be acquired through non-invasive surface...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaluddin, Nurul Fauzani, Ahmad, Siti Anom, Mohd Noor, Samsul Bahari, Wan Hasan, Wan Zuha
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/39319/1/Flexible%20bio-signals%20channels%20acquisition%20system%20for%20ECG%20and%20EMG%20application.pdf
http://psasir.upm.edu.my/id/eprint/39319/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.39319
record_format eprints
spelling my.upm.eprints.393192018-03-30T07:05:58Z http://psasir.upm.edu.my/id/eprint/39319/ Flexible bio-signals channels acquisition system for ECG and EMG application Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha Each nerves and muscles of human body will generate potentials, voltages, and electrical field strength and known as bio signals such as electrocardiograph (ECG), electromyography (EMG), electroencephalogram (EEG), and electrooculogram (EOG). The signals may be acquired through non-invasive surface Ag/Ag Cl applications although the generated signals exist in very low levels of voltages. All the bio signals may be obtained from basic designs of instrumentation amplifier with the help of Ag/Ag Cl electrodes. However, different frequency band, interference, amplitude and strength may give huge challenges to the acquisition system. This paper provides instrumentation amplification design, include with the design concept to allow for flexible channels. There are lots of advantages from the proposed design such as minimal additional cost for additional channels used and circuit design modification or replacement. To suits bio-signals frequency bandwidth need, digital filter design in Labview software is added, as a part of acquisition system and to discard unwanted signals outside frequency bandwidth.. For now, the design is able to demonstrate to acquire two bio-potentials signals; ECG and EMG signals. IEEE 2014 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/39319/1/Flexible%20bio-signals%20channels%20acquisition%20system%20for%20ECG%20and%20EMG%20application.pdf Jamaluddin, Nurul Fauzani and Ahmad, Siti Anom and Mohd Noor, Samsul Bahari and Wan Hasan, Wan Zuha (2014) Flexible bio-signals channels acquisition system for ECG and EMG application. In: 2014 IEEE Student Conference on Research and Development (SCOReD), 16-17 Dec. 2014, Penang, Malaysia. . 10.1109/SCORED.2014.7072996
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Each nerves and muscles of human body will generate potentials, voltages, and electrical field strength and known as bio signals such as electrocardiograph (ECG), electromyography (EMG), electroencephalogram (EEG), and electrooculogram (EOG). The signals may be acquired through non-invasive surface Ag/Ag Cl applications although the generated signals exist in very low levels of voltages. All the bio signals may be obtained from basic designs of instrumentation amplifier with the help of Ag/Ag Cl electrodes. However, different frequency band, interference, amplitude and strength may give huge challenges to the acquisition system. This paper provides instrumentation amplification design, include with the design concept to allow for flexible channels. There are lots of advantages from the proposed design such as minimal additional cost for additional channels used and circuit design modification or replacement. To suits bio-signals frequency bandwidth need, digital filter design in Labview software is added, as a part of acquisition system and to discard unwanted signals outside frequency bandwidth.. For now, the design is able to demonstrate to acquire two bio-potentials signals; ECG and EMG signals.
format Conference or Workshop Item
author Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
spellingShingle Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
Flexible bio-signals channels acquisition system for ECG and EMG application
author_facet Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
author_sort Jamaluddin, Nurul Fauzani
title Flexible bio-signals channels acquisition system for ECG and EMG application
title_short Flexible bio-signals channels acquisition system for ECG and EMG application
title_full Flexible bio-signals channels acquisition system for ECG and EMG application
title_fullStr Flexible bio-signals channels acquisition system for ECG and EMG application
title_full_unstemmed Flexible bio-signals channels acquisition system for ECG and EMG application
title_sort flexible bio-signals channels acquisition system for ecg and emg application
publisher IEEE
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/39319/1/Flexible%20bio-signals%20channels%20acquisition%20system%20for%20ECG%20and%20EMG%20application.pdf
http://psasir.upm.edu.my/id/eprint/39319/
_version_ 1643832389295669248