Two electrodes system: performance on ECG, FECG and EMG detection

Recording of biopotential signals is uneasy as interference and noise can come from the preparation of the subject, environment setting and other biological signal. The circuit design in acquisition system must good and meets specification as is not distort original signal and safe to patient. Class...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaluddin, Nurul Fauzani, Ahmad, Siti Anom, Mohd Noor, Samsul Bahari, Wan Hasan, Wan Zuha, Kamal, Mustaffa, Aminnudin, Azan, Abd. Kadir Bakti, Zulkifli
Format: Conference or Workshop Item
Language:English
Published: IEEE 2013
Online Access:http://psasir.upm.edu.my/id/eprint/41483/1/Two%20electrodes%20system%20performance%20on%20ECG%2C%20FECG%20and%20EMG%20detection.pdf
http://psasir.upm.edu.my/id/eprint/41483/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.41483
record_format eprints
spelling my.upm.eprints.414832019-06-10T02:48:05Z http://psasir.upm.edu.my/id/eprint/41483/ Two electrodes system: performance on ECG, FECG and EMG detection Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha Kamal, Mustaffa Aminnudin, Azan Abd. Kadir Bakti, Zulkifli Recording of biopotential signals is uneasy as interference and noise can come from the preparation of the subject, environment setting and other biological signal. The circuit design in acquisition system must good and meets specification as is not distort original signal and safe to patient. Classic design of biosignal acquisition system usually use third electrode as reference potential. The third electrode is not picking up the biological signal and placed quite far from the measured signal as it can help to remove common mode signal. However, sometime the third electrode will limit patient movement since some of the experiment requires the patient or subject do several kind of movement during signals recording. Therefore, two electrodes system without third electrode may provide mobility and comfort since number of electrode patched on the body is reduced. Though several previous researches have implemented the two electrodes system, but they only tested on electrocardiogram. Hence, the main contribution of this paper is investigating the ability and performance of the proposed system on fetal electrocardiogram and electromyogram detection since the challenges to detect both signals are different compare to electrocardiogram. The electrocardiogram, fetal electrocardiogram and electromyogram are successfully detected using the propose system but with several filtering stages. The performance evaluation include signal to noise ratio after the filtering stage and accuracy of the signal detection. IEEE 2013 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/41483/1/Two%20electrodes%20system%20performance%20on%20ECG%2C%20FECG%20and%20EMG%20detection.pdf Jamaluddin, Nurul Fauzani and Ahmad, Siti Anom and Mohd Noor, Samsul Bahari and Wan Hasan, Wan Zuha and Kamal, Mustaffa and Aminnudin, Azan and Abd. Kadir Bakti, Zulkifli (2013) Two electrodes system: performance on ECG, FECG and EMG detection. In: 2013 IEEE Student Conference on Research and Development (SCOReD), 16-17 Dec. 2013, Putrajaya, Malaysia. (pp. 506-510). 10.1109/SCOReD.2013.7002642
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Recording of biopotential signals is uneasy as interference and noise can come from the preparation of the subject, environment setting and other biological signal. The circuit design in acquisition system must good and meets specification as is not distort original signal and safe to patient. Classic design of biosignal acquisition system usually use third electrode as reference potential. The third electrode is not picking up the biological signal and placed quite far from the measured signal as it can help to remove common mode signal. However, sometime the third electrode will limit patient movement since some of the experiment requires the patient or subject do several kind of movement during signals recording. Therefore, two electrodes system without third electrode may provide mobility and comfort since number of electrode patched on the body is reduced. Though several previous researches have implemented the two electrodes system, but they only tested on electrocardiogram. Hence, the main contribution of this paper is investigating the ability and performance of the proposed system on fetal electrocardiogram and electromyogram detection since the challenges to detect both signals are different compare to electrocardiogram. The electrocardiogram, fetal electrocardiogram and electromyogram are successfully detected using the propose system but with several filtering stages. The performance evaluation include signal to noise ratio after the filtering stage and accuracy of the signal detection.
format Conference or Workshop Item
author Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
Kamal, Mustaffa
Aminnudin, Azan
Abd. Kadir Bakti, Zulkifli
spellingShingle Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
Kamal, Mustaffa
Aminnudin, Azan
Abd. Kadir Bakti, Zulkifli
Two electrodes system: performance on ECG, FECG and EMG detection
author_facet Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
Kamal, Mustaffa
Aminnudin, Azan
Abd. Kadir Bakti, Zulkifli
author_sort Jamaluddin, Nurul Fauzani
title Two electrodes system: performance on ECG, FECG and EMG detection
title_short Two electrodes system: performance on ECG, FECG and EMG detection
title_full Two electrodes system: performance on ECG, FECG and EMG detection
title_fullStr Two electrodes system: performance on ECG, FECG and EMG detection
title_full_unstemmed Two electrodes system: performance on ECG, FECG and EMG detection
title_sort two electrodes system: performance on ecg, fecg and emg detection
publisher IEEE
publishDate 2013
url http://psasir.upm.edu.my/id/eprint/41483/1/Two%20electrodes%20system%20performance%20on%20ECG%2C%20FECG%20and%20EMG%20detection.pdf
http://psasir.upm.edu.my/id/eprint/41483/
_version_ 1643833010359894016