Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code

Radioactive Particle Tracking (RPT) is non-invasive evaluation technique capable of visualising and tracking the motion of the identified phase in bubble column reactor. The single radioactive particle emits γ-ray, and its movement in the column is tracked with the aid of arrays radiation detectors....

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Yunos, Mohd Amirul Syafiq, Anak Usang, Mark Dennis, Ithnin, Hanafi, Hussain, Siti Aslina, Mohamed Yusoff, Hamdan, Sipaun, Susan
Format: Article
Language:English
Published: European Journals 2018
Online Access:http://psasir.upm.edu.my/id/eprint/73722/1/Reconstruction%20algorithm%20of%20calibration%20map%20for%20RPT%20technique%20in%20quadrilateral%20bubble%20column%20reactor%20using%20MCNPX%20code.pdf
http://psasir.upm.edu.my/id/eprint/73722/
https://www.ejers.org/index.php/ejers/article/view/583/229
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.73722
record_format eprints
spelling my.upm.eprints.737222020-05-07T19:17:56Z http://psasir.upm.edu.my/id/eprint/73722/ Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code Mohd Yunos, Mohd Amirul Syafiq Anak Usang, Mark Dennis Ithnin, Hanafi Hussain, Siti Aslina Mohamed Yusoff, Hamdan Sipaun, Susan Radioactive Particle Tracking (RPT) is non-invasive evaluation technique capable of visualising and tracking the motion of the identified phase in bubble column reactor. The single radioactive particle emits γ-ray, and its movement in the column is tracked with the aid of arrays radiation detectors. In this study, Monte Carlo approach was programmed to reconstruct the particle tracer position so-called calibration map. The iterative reconstruction algorithms is used to generate and calculate the 2600 coordinates of calibration map from the number of photon counts from the ten NaI scintillation detectors. To validate the simulation precision, a spiral trajectory of radioactive particle inside the bubble column region consist of 84 grid point locations of the particle were applied. Calibration algorithm was developed for radioactive isotopes Au-198 and Sc-46 particle position verification and determination of statistical uncertainty from the introduction of a various number of primary photon emission. The result of the studies proved that higher number of particles used in the algorithm for position reconstruction gives more accuracy and we found that the Sc-46 obtain more accurate calculation and shows low statistical level than Au-198 particle. The outcome of this simulation based on random sampling from Monte Carlo N-Particle Extended (MCNPX) demonstrated that the calibration map could successfully be implemented in RPT technique to observe the dynamic movement of radioactive particle which represents the tracked media in the quadrilateral bubble column. European Journals 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/73722/1/Reconstruction%20algorithm%20of%20calibration%20map%20for%20RPT%20technique%20in%20quadrilateral%20bubble%20column%20reactor%20using%20MCNPX%20code.pdf Mohd Yunos, Mohd Amirul Syafiq and Anak Usang, Mark Dennis and Ithnin, Hanafi and Hussain, Siti Aslina and Mohamed Yusoff, Hamdan and Sipaun, Susan (2018) Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code. European Journal of Engineering Research and Sciences, 3 (1). 20 - 27. ISSN 1450-202X https://www.ejers.org/index.php/ejers/article/view/583/229 10.24018/ejers.2018.3.1.583
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Radioactive Particle Tracking (RPT) is non-invasive evaluation technique capable of visualising and tracking the motion of the identified phase in bubble column reactor. The single radioactive particle emits γ-ray, and its movement in the column is tracked with the aid of arrays radiation detectors. In this study, Monte Carlo approach was programmed to reconstruct the particle tracer position so-called calibration map. The iterative reconstruction algorithms is used to generate and calculate the 2600 coordinates of calibration map from the number of photon counts from the ten NaI scintillation detectors. To validate the simulation precision, a spiral trajectory of radioactive particle inside the bubble column region consist of 84 grid point locations of the particle were applied. Calibration algorithm was developed for radioactive isotopes Au-198 and Sc-46 particle position verification and determination of statistical uncertainty from the introduction of a various number of primary photon emission. The result of the studies proved that higher number of particles used in the algorithm for position reconstruction gives more accuracy and we found that the Sc-46 obtain more accurate calculation and shows low statistical level than Au-198 particle. The outcome of this simulation based on random sampling from Monte Carlo N-Particle Extended (MCNPX) demonstrated that the calibration map could successfully be implemented in RPT technique to observe the dynamic movement of radioactive particle which represents the tracked media in the quadrilateral bubble column.
format Article
author Mohd Yunos, Mohd Amirul Syafiq
Anak Usang, Mark Dennis
Ithnin, Hanafi
Hussain, Siti Aslina
Mohamed Yusoff, Hamdan
Sipaun, Susan
spellingShingle Mohd Yunos, Mohd Amirul Syafiq
Anak Usang, Mark Dennis
Ithnin, Hanafi
Hussain, Siti Aslina
Mohamed Yusoff, Hamdan
Sipaun, Susan
Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
author_facet Mohd Yunos, Mohd Amirul Syafiq
Anak Usang, Mark Dennis
Ithnin, Hanafi
Hussain, Siti Aslina
Mohamed Yusoff, Hamdan
Sipaun, Susan
author_sort Mohd Yunos, Mohd Amirul Syafiq
title Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
title_short Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
title_full Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
title_fullStr Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
title_full_unstemmed Reconstruction algorithm of calibration map for RPT technique in quadrilateral bubble column reactor using MCNPX code
title_sort reconstruction algorithm of calibration map for rpt technique in quadrilateral bubble column reactor using mcnpx code
publisher European Journals
publishDate 2018
url http://psasir.upm.edu.my/id/eprint/73722/1/Reconstruction%20algorithm%20of%20calibration%20map%20for%20RPT%20technique%20in%20quadrilateral%20bubble%20column%20reactor%20using%20MCNPX%20code.pdf
http://psasir.upm.edu.my/id/eprint/73722/
https://www.ejers.org/index.php/ejers/article/view/583/229
_version_ 1669008828984721408