Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying

Repeated use of frying oil has been proven hazardous due to the degradation process that changes the quality of the oil. In this study, an interdigitated electrode (IDE) sensor was designed to evaluate palm olein degradation during deep fat frying at several frying intervals by measuring the changes...

Full description

Saved in:
Bibliographic Details
Main Authors: Khaled, Alfadhl Yahya, Abd Aziz, Samsuzana, Rokhani, Fakhrul Zaman, Ibrahim, Nur Ul Atikah
Format: Article
Language:English
Published: American Society of Agricultural and Biological Engineers 2018
Online Access:http://psasir.upm.edu.my/id/eprint/74714/1/Interdigitated%20electrode.pdf
http://psasir.upm.edu.my/id/eprint/74714/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.74714
record_format eprints
spelling my.upm.eprints.747142020-03-17T08:13:15Z http://psasir.upm.edu.my/id/eprint/74714/ Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying Khaled, Alfadhl Yahya Abd Aziz, Samsuzana Rokhani, Fakhrul Zaman Ibrahim, Nur Ul Atikah Repeated use of frying oil has been proven hazardous due to the degradation process that changes the quality of the oil. In this study, an interdigitated electrode (IDE) sensor was designed to evaluate palm olein degradation during deep fat frying at several frying intervals by measuring the changes in the oil‘s electrical properties. The frying experiment was carried out in batches. In total, 150 batches (150 g batch-1) of French fries were fried over five days. Oil samples were collected (150 mL) after every five frying cycles. The impedance values were measured at 35°C and 45°C using the IDE sensor connected to aninductance (L), capacitance (C), and resistance (R) LCR meter with five frequency levels (100 Hz, 1 kHz, 10 kHz, 20 kHz, and 100 kHz). The total polar compounds (TPC) of each oil sample were measured with a Testo 270 frying oil tester, while the viscosity was measured with a viscometer. The impedance values were found to be significantly different at 35°C and 45°C as well as at different frequency levels (p < 0.0001). For individual frequency analysis, the regression equation obtained the best results at 35°C (with RMSE of 1.21%) and 1.33 mPa.s for TPC and viscosity, respectively. The results indicated that the designed IDE sensor has good potential as a simple and inexpensive method for monitoring palm olein degradation during deep fat frying. American Society of Agricultural and Biological Engineers 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/74714/1/Interdigitated%20electrode.pdf Khaled, Alfadhl Yahya and Abd Aziz, Samsuzana and Rokhani, Fakhrul Zaman and Ibrahim, Nur Ul Atikah (2018) Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying. Transactions of the ASABE, 61 (1). 15 - 24. ISSN 2151-0032 10.13031/trans.11840
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Repeated use of frying oil has been proven hazardous due to the degradation process that changes the quality of the oil. In this study, an interdigitated electrode (IDE) sensor was designed to evaluate palm olein degradation during deep fat frying at several frying intervals by measuring the changes in the oil‘s electrical properties. The frying experiment was carried out in batches. In total, 150 batches (150 g batch-1) of French fries were fried over five days. Oil samples were collected (150 mL) after every five frying cycles. The impedance values were measured at 35°C and 45°C using the IDE sensor connected to aninductance (L), capacitance (C), and resistance (R) LCR meter with five frequency levels (100 Hz, 1 kHz, 10 kHz, 20 kHz, and 100 kHz). The total polar compounds (TPC) of each oil sample were measured with a Testo 270 frying oil tester, while the viscosity was measured with a viscometer. The impedance values were found to be significantly different at 35°C and 45°C as well as at different frequency levels (p < 0.0001). For individual frequency analysis, the regression equation obtained the best results at 35°C (with RMSE of 1.21%) and 1.33 mPa.s for TPC and viscosity, respectively. The results indicated that the designed IDE sensor has good potential as a simple and inexpensive method for monitoring palm olein degradation during deep fat frying.
format Article
author Khaled, Alfadhl Yahya
Abd Aziz, Samsuzana
Rokhani, Fakhrul Zaman
Ibrahim, Nur Ul Atikah
spellingShingle Khaled, Alfadhl Yahya
Abd Aziz, Samsuzana
Rokhani, Fakhrul Zaman
Ibrahim, Nur Ul Atikah
Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
author_facet Khaled, Alfadhl Yahya
Abd Aziz, Samsuzana
Rokhani, Fakhrul Zaman
Ibrahim, Nur Ul Atikah
author_sort Khaled, Alfadhl Yahya
title Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
title_short Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
title_full Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
title_fullStr Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
title_full_unstemmed Interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
title_sort interdigitated electrode for degradation assessment of palm olein during batch deep fat frying
publisher American Society of Agricultural and Biological Engineers
publishDate 2018
url http://psasir.upm.edu.my/id/eprint/74714/1/Interdigitated%20electrode.pdf
http://psasir.upm.edu.my/id/eprint/74714/
_version_ 1662756498408734720