Frequency response analysis technique for induction motor short circuit faults detection
The paper presents the description for diagnostic methods of induction motor's stator windings fault. The presented methods use Frequency Response Analysis (FRA) technique for detection of Winding Faults in Induction Motor . This method is previously reliable method for faults diagnosis and det...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2020
|
Online Access: | http://psasir.upm.edu.my/id/eprint/89071/1/MOTOR.pdf http://psasir.upm.edu.my/id/eprint/89071/ http://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20811 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.89071 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.890712021-09-21T23:22:10Z http://psasir.upm.edu.my/id/eprint/89071/ Frequency response analysis technique for induction motor short circuit faults detection A. A., Alawady M. F. M., Yousof Azis, Norhafiz Talib, Mohd Aizam The paper presents the description for diagnostic methods of induction motor's stator windings fault. The presented methods use Frequency Response Analysis (FRA) technique for detection of Winding Faults in Induction Motor . This method is previously reliable method for faults diagnosis and detection in many parts of transformers including transformer windings. In this paper, this method was used for motor windings faults detection. This paper presents the FRA response interpretation on internal short circuit (SC) fault at stator winding on three cases studies of different three-phase induction motors (TPIM), were analysed according to two status: healthy induction motor at normal winding status and same motor with windings shorted of main windings. A conclusion of this paper provides the interpretation of and validation the FRA response due to internal SC fault case by using NCEPRI algorithm, which is considered as one of certified statistical indicators. The proposed method in this paper had a useful result for detect and diagnosis of stator windings faults of TPIM. The applications of developed method can be used to detece the other machines types faults. Institute of Advanced Engineering and Science 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/89071/1/MOTOR.pdf A. A., Alawady and M. F. M., Yousof and Azis, Norhafiz and Talib, Mohd Aizam (2020) Frequency response analysis technique for induction motor short circuit faults detection. International Journal of Power Electronics and Drive Systems, 11 (3). 1653 - 1659. ISSN 2088-8694; ESSN: 2722-256X http://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20811 10.11591/ijpeds.v11.i3.pp1653-1659 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
The paper presents the description for diagnostic methods of induction motor's stator windings fault. The presented methods use Frequency Response Analysis (FRA) technique for detection of Winding Faults in Induction Motor . This method is previously reliable method for faults diagnosis and detection in many parts of transformers including transformer windings. In this paper, this method was used for motor windings faults detection. This paper presents the FRA response interpretation on internal short circuit (SC) fault at stator winding on three cases studies of different three-phase induction motors (TPIM), were analysed according to two status: healthy induction motor at normal winding status and same motor with windings shorted of main windings. A conclusion of this paper provides the interpretation of and validation the FRA response due to internal SC fault case by using NCEPRI algorithm, which is considered as one of certified statistical indicators. The proposed method in this paper had a useful result for detect and diagnosis of stator windings faults of TPIM. The applications of developed method can be used to detece the other machines types faults. |
format |
Article |
author |
A. A., Alawady M. F. M., Yousof Azis, Norhafiz Talib, Mohd Aizam |
spellingShingle |
A. A., Alawady M. F. M., Yousof Azis, Norhafiz Talib, Mohd Aizam Frequency response analysis technique for induction motor short circuit faults detection |
author_facet |
A. A., Alawady M. F. M., Yousof Azis, Norhafiz Talib, Mohd Aizam |
author_sort |
A. A., Alawady |
title |
Frequency response analysis technique for induction motor short circuit faults detection |
title_short |
Frequency response analysis technique for induction motor short circuit faults detection |
title_full |
Frequency response analysis technique for induction motor short circuit faults detection |
title_fullStr |
Frequency response analysis technique for induction motor short circuit faults detection |
title_full_unstemmed |
Frequency response analysis technique for induction motor short circuit faults detection |
title_sort |
frequency response analysis technique for induction motor short circuit faults detection |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2020 |
url |
http://psasir.upm.edu.my/id/eprint/89071/1/MOTOR.pdf http://psasir.upm.edu.my/id/eprint/89071/ http://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20811 |
_version_ |
1712286751134842880 |