Surface Engineering Of Titanium Based Metal For Cell Interaction

This research focused on the titanium surface modification with nanotopography morphology of TiO2 nanotubes. Cell-metal interaction between TiO2 nanotubes and PA6 bone marrow stromal cells were studied to understand the TiO2 nanotubes parameters that affect the cell growth. To achieve objective of t...

Full description

Saved in:
Bibliographic Details
Main Author: Hazan , Roshasnorlyza
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.usm.my/41126/1/ROSHASNORLYZA_BINTI_HAZAN_24_Pages.pdf
http://eprints.usm.my/41126/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.41126
record_format eprints
spelling my.usm.eprints.41126 http://eprints.usm.my/41126/ Surface Engineering Of Titanium Based Metal For Cell Interaction Hazan , Roshasnorlyza TN263-271 Mineral deposits. Metallic ore deposits. Prospecting This research focused on the titanium surface modification with nanotopography morphology of TiO2 nanotubes. Cell-metal interaction between TiO2 nanotubes and PA6 bone marrow stromal cells were studied to understand the TiO2 nanotubes parameters that affect the cell growth. To achieve objective of this research work, titanium foil was transformed into different dimensionalities of TiO2 nanotubes via simple anodization method and characterized. TiO2 nanotubes with inner diameter of 25 nm to 110 nm were successfully developed within 10 V to 40 V. Corrosion resistance was higher for sample anodizes at 10 V (25 nm-diameters). The length of the TiO2 nanotubes arrays were 2.2 μm after 3 hours anodization. Anatase, anataserutile and rutile phase was observed when TiO2 nanotubes subjected to anneal at 300 °C, 600 °C and 700 °C. Tubular structure destroy when anneal at 700 °C. Anatase phase give higher corrosion resistance because crystallized barrier oxide layer hinder the corrosion activity (corrosion rate = 0.31 nm/year). Cell morphology, adhesion,viability, immunocytochemistry, alkaline phosphatase activity, calcium deposition, Western Blot and immunophenotyping were done to evaluate PA6 cells interaction on TiO2 nanotubes accordingly. From this study, 45 nm-diameter, 2.2 μm-length nanotube and anatase-rutile mixture phase enhanced the PA6 cells growth. No materials elution after 3 days incubation with PA6 cells observed. The protein concentrations on TiO2 nanotubes were significantly higher than control due to large surface area and binding sites for cells to anchorage the substrate. Immunostaining expression for cytokeratin, Bromodeoxyuridine, CD34, IBMR3 and PI was positive on entire samples. From immunophenotyping analysis, PA6 cells were positive on CD49e, CD51 and CD73, suggested that PA6 cells on TiO2 nanotube arrays positively involved in extracellular matrix adhesion, bone marrow stromal cells interaction, immune system and mesenchymal stem cells differentiate. Importantly, fluorescence image shows PA6 cells cultured on TiO2 nanotubes did not have much alteration as compared to control with regard of no significant different from the fluorescence intensity. After 14 days, hydroxyapatite fully covered TiO2 nanotubes surface and enhance the PA6 cell growth and viability. These findings indicate that fine-tuning TiO2 nanotubes will be essential parameter in optimizing PA6 cell interaction. 2014 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/41126/1/ROSHASNORLYZA_BINTI_HAZAN_24_Pages.pdf Hazan , Roshasnorlyza (2014) Surface Engineering Of Titanium Based Metal For Cell Interaction. PhD thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic TN263-271 Mineral deposits. Metallic ore deposits. Prospecting
spellingShingle TN263-271 Mineral deposits. Metallic ore deposits. Prospecting
Hazan , Roshasnorlyza
Surface Engineering Of Titanium Based Metal For Cell Interaction
description This research focused on the titanium surface modification with nanotopography morphology of TiO2 nanotubes. Cell-metal interaction between TiO2 nanotubes and PA6 bone marrow stromal cells were studied to understand the TiO2 nanotubes parameters that affect the cell growth. To achieve objective of this research work, titanium foil was transformed into different dimensionalities of TiO2 nanotubes via simple anodization method and characterized. TiO2 nanotubes with inner diameter of 25 nm to 110 nm were successfully developed within 10 V to 40 V. Corrosion resistance was higher for sample anodizes at 10 V (25 nm-diameters). The length of the TiO2 nanotubes arrays were 2.2 μm after 3 hours anodization. Anatase, anataserutile and rutile phase was observed when TiO2 nanotubes subjected to anneal at 300 °C, 600 °C and 700 °C. Tubular structure destroy when anneal at 700 °C. Anatase phase give higher corrosion resistance because crystallized barrier oxide layer hinder the corrosion activity (corrosion rate = 0.31 nm/year). Cell morphology, adhesion,viability, immunocytochemistry, alkaline phosphatase activity, calcium deposition, Western Blot and immunophenotyping were done to evaluate PA6 cells interaction on TiO2 nanotubes accordingly. From this study, 45 nm-diameter, 2.2 μm-length nanotube and anatase-rutile mixture phase enhanced the PA6 cells growth. No materials elution after 3 days incubation with PA6 cells observed. The protein concentrations on TiO2 nanotubes were significantly higher than control due to large surface area and binding sites for cells to anchorage the substrate. Immunostaining expression for cytokeratin, Bromodeoxyuridine, CD34, IBMR3 and PI was positive on entire samples. From immunophenotyping analysis, PA6 cells were positive on CD49e, CD51 and CD73, suggested that PA6 cells on TiO2 nanotube arrays positively involved in extracellular matrix adhesion, bone marrow stromal cells interaction, immune system and mesenchymal stem cells differentiate. Importantly, fluorescence image shows PA6 cells cultured on TiO2 nanotubes did not have much alteration as compared to control with regard of no significant different from the fluorescence intensity. After 14 days, hydroxyapatite fully covered TiO2 nanotubes surface and enhance the PA6 cell growth and viability. These findings indicate that fine-tuning TiO2 nanotubes will be essential parameter in optimizing PA6 cell interaction.
format Thesis
author Hazan , Roshasnorlyza
author_facet Hazan , Roshasnorlyza
author_sort Hazan , Roshasnorlyza
title Surface Engineering Of Titanium Based Metal For Cell Interaction
title_short Surface Engineering Of Titanium Based Metal For Cell Interaction
title_full Surface Engineering Of Titanium Based Metal For Cell Interaction
title_fullStr Surface Engineering Of Titanium Based Metal For Cell Interaction
title_full_unstemmed Surface Engineering Of Titanium Based Metal For Cell Interaction
title_sort surface engineering of titanium based metal for cell interaction
publishDate 2014
url http://eprints.usm.my/41126/1/ROSHASNORLYZA_BINTI_HAZAN_24_Pages.pdf
http://eprints.usm.my/41126/
_version_ 1643710135228432384