Comparison of CT number between conventional CBCT and imasim software

The aim of this study was to compare the CT number between the conventional Cone Beam Computed Tomography (CBCT) and ImaSim simulation software. The CT numbers in CBCT were performed by using CIRS 062 M electron density phantoms with four types of tissue equivalent plug density phantoms ranging...

Full description

Saved in:
Bibliographic Details
Main Author: Ahamad, Nor Fadhilah
Format: Monograph
Language:English
Published: Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2015
Subjects:
Online Access:http://eprints.usm.my/57944/1/NOR%20FADHILAH%20BINTI%20AHAMAD-24%20PAGES.pdf
http://eprints.usm.my/57944/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.57944
record_format eprints
spelling my.usm.eprints.57944 http://eprints.usm.my/57944/ Comparison of CT number between conventional CBCT and imasim software Ahamad, Nor Fadhilah QA75-76.95 Calculating Machines The aim of this study was to compare the CT number between the conventional Cone Beam Computed Tomography (CBCT) and ImaSim simulation software. The CT numbers in CBCT were performed by using CIRS 062 M electron density phantoms with four types of tissue equivalent plug density phantoms ranging from 0 g/cm3 to 1.61 g/cm3 based on the common tissues in the oral cavity. The CT numbers of tissue equivalent density plugs were of air, adipose, water and bone were compared between CBCT and ImaSim software at 80 kVp and 10 mAs. 15 slices of CBCT images with slice thickness of approximately 1.0 mm are obtained from central axis of phantom were selected to measure the average CT number by drawing a region of interest (ROI) on every slice. The images of ImaSim were obtained by simulation of CBCT at similar phantom set up and CBCT exposure factors. The measurement of chi-square 'goodness of fit' was used to determine the closeness of CT numbers among theoretical, Planmeca Romexis CBCT and ImaSim. The results showed that the x2 values of CT numbers of theoretical value against Planmeca Romexis CBCT were between 0.651 and 5.206 while the x2 values of theoretical value against lmasim CBCT was between 3.738 and 42.201. However, the range of x2 for Planmeca Romexis CBCT vs lmaSim CBCT was between 1.877 and 58.887. In conclusion, the high density tissues such as bone gave the highest degree of closeness of CT numbers between Planmeca Romexis CBCT and lmaSim. Therefore, low density tissues are best applied in ImaSim CBCT simulation. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2015 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57944/1/NOR%20FADHILAH%20BINTI%20AHAMAD-24%20PAGES.pdf Ahamad, Nor Fadhilah (2015) Comparison of CT number between conventional CBCT and imasim software. Project Report. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic QA75-76.95 Calculating Machines
spellingShingle QA75-76.95 Calculating Machines
Ahamad, Nor Fadhilah
Comparison of CT number between conventional CBCT and imasim software
description The aim of this study was to compare the CT number between the conventional Cone Beam Computed Tomography (CBCT) and ImaSim simulation software. The CT numbers in CBCT were performed by using CIRS 062 M electron density phantoms with four types of tissue equivalent plug density phantoms ranging from 0 g/cm3 to 1.61 g/cm3 based on the common tissues in the oral cavity. The CT numbers of tissue equivalent density plugs were of air, adipose, water and bone were compared between CBCT and ImaSim software at 80 kVp and 10 mAs. 15 slices of CBCT images with slice thickness of approximately 1.0 mm are obtained from central axis of phantom were selected to measure the average CT number by drawing a region of interest (ROI) on every slice. The images of ImaSim were obtained by simulation of CBCT at similar phantom set up and CBCT exposure factors. The measurement of chi-square 'goodness of fit' was used to determine the closeness of CT numbers among theoretical, Planmeca Romexis CBCT and ImaSim. The results showed that the x2 values of CT numbers of theoretical value against Planmeca Romexis CBCT were between 0.651 and 5.206 while the x2 values of theoretical value against lmasim CBCT was between 3.738 and 42.201. However, the range of x2 for Planmeca Romexis CBCT vs lmaSim CBCT was between 1.877 and 58.887. In conclusion, the high density tissues such as bone gave the highest degree of closeness of CT numbers between Planmeca Romexis CBCT and lmaSim. Therefore, low density tissues are best applied in ImaSim CBCT simulation.
format Monograph
author Ahamad, Nor Fadhilah
author_facet Ahamad, Nor Fadhilah
author_sort Ahamad, Nor Fadhilah
title Comparison of CT number between conventional CBCT and imasim software
title_short Comparison of CT number between conventional CBCT and imasim software
title_full Comparison of CT number between conventional CBCT and imasim software
title_fullStr Comparison of CT number between conventional CBCT and imasim software
title_full_unstemmed Comparison of CT number between conventional CBCT and imasim software
title_sort comparison of ct number between conventional cbct and imasim software
publisher Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia
publishDate 2015
url http://eprints.usm.my/57944/1/NOR%20FADHILAH%20BINTI%20AHAMAD-24%20PAGES.pdf
http://eprints.usm.my/57944/
_version_ 1762962386572017664