Effects of Process Temperature and Time on the Properties of Microwave Plasma Nitrided Ti-6Al-4V Alloy
Titanium alloy (e.g. Ti-6Al-4V) has an excellent combination of properties. However in many cases, the application is limited because of the poor wear property. In this work, a surface modification (plasma nitriding) is carried out to improve the surface properties of Ti-6Al-4V, as a treatment pri...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Putra Malaysia
2013
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/10951/1/pertanika_yy2013.pdf http://eprints.utem.edu.my/id/eprint/10951/ http://www.pertanika.upm.edu.my/JST.php |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknikal Malaysia Melaka |
Language: | English |
id |
my.utem.eprints.10951 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.109512015-05-28T04:14:27Z http://eprints.utem.edu.my/id/eprint/10951/ Effects of Process Temperature and Time on the Properties of Microwave Plasma Nitrided Ti-6Al-4V Alloy Yusuf, Y. Juoi, J. M. Rosli, Z. M. Kwan , W. L. Mahamud, Z. TJ Mechanical engineering and machinery Titanium alloy (e.g. Ti-6Al-4V) has an excellent combination of properties. However in many cases, the application is limited because of the poor wear property. In this work, a surface modification (plasma nitriding) is carried out to improve the surface properties of Ti-6Al-4V, as a treatment prior to a hardcoating deposition, leading to a duplex coating system. This is an effort to improve the surface and near surface property of Ti-6Al-4V. Plasma nitriding is performed utilizing microwave plasma method in 25% Ar- 75% N2 atmosphere at temperatures of 600°C and 700°C for different processing times (1, 3 and 5 hours). The phase and microstructure of plasma nitrided substrate were characterized by using X-ray diffraction (XRD) and Scanning electron microscopy (SEM). The plasma nitrided Ti-6Al-4V properties (surface roughness, surface hardness and case depth) were determined using profilometer and microhardness, respectively. Results obtained showed a significant increase on the surface hardness of Ti-6Al-4V. This is due to the formation of TiN and Ti2N phases in the form of compound layer. Besides, it shows that the diffusion of nitrogen into the Ti-6Al-4V substrate produces case depth up to 130 μm and this contributes to the improvement of the near surface hardness due to the changes in the microstructures. It was also found that the surface hardness and surface roughness increased with the increases in the process temperature and times. Universiti Putra Malaysia 2013 Article PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/10951/1/pertanika_yy2013.pdf Yusuf, Y. and Juoi, J. M. and Rosli, Z. M. and Kwan , W. L. and Mahamud, Z. (2013) Effects of Process Temperature and Time on the Properties of Microwave Plasma Nitrided Ti-6Al-4V Alloy. Pertanika Journal of SCience and Technology, 21 (1). pp. 45-58. ISSN 0128-7680 http://www.pertanika.upm.edu.my/JST.php |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Yusuf, Y. Juoi, J. M. Rosli, Z. M. Kwan , W. L. Mahamud, Z. Effects of Process Temperature and Time on the Properties of Microwave Plasma Nitrided Ti-6Al-4V Alloy |
description |
Titanium alloy (e.g. Ti-6Al-4V) has an excellent combination of properties. However in many cases,
the application is limited because of the poor wear property. In this work, a surface modification
(plasma nitriding) is carried out to improve the surface properties of Ti-6Al-4V, as a treatment prior to a
hardcoating deposition, leading to a duplex coating system. This is an effort to improve the surface and
near surface property of Ti-6Al-4V. Plasma nitriding is performed utilizing microwave plasma method
in 25% Ar- 75% N2 atmosphere at temperatures of 600°C and 700°C for different processing times (1,
3 and 5 hours). The phase and microstructure of plasma nitrided substrate were characterized by using
X-ray diffraction (XRD) and Scanning electron microscopy (SEM). The plasma nitrided Ti-6Al-4V
properties (surface roughness, surface hardness and case depth) were determined using profilometer
and microhardness, respectively. Results obtained showed a significant increase on the surface hardness
of Ti-6Al-4V. This is due to the formation of TiN and Ti2N phases in the form of compound layer.
Besides, it shows that the diffusion of nitrogen into the Ti-6Al-4V substrate produces case depth up to
130 μm and this contributes to the improvement of the near surface hardness due to the changes in the
microstructures. It was also found that the surface hardness and surface roughness increased with the
increases in the process temperature and times. |
format |
Article |
author |
Yusuf, Y. Juoi, J. M. Rosli, Z. M. Kwan , W. L. Mahamud, Z. |
author_facet |
Yusuf, Y. Juoi, J. M. Rosli, Z. M. Kwan , W. L. Mahamud, Z. |
author_sort |
Yusuf, Y. |
title |
Effects of Process Temperature and Time on the Properties of
Microwave Plasma Nitrided Ti-6Al-4V Alloy |
title_short |
Effects of Process Temperature and Time on the Properties of
Microwave Plasma Nitrided Ti-6Al-4V Alloy |
title_full |
Effects of Process Temperature and Time on the Properties of
Microwave Plasma Nitrided Ti-6Al-4V Alloy |
title_fullStr |
Effects of Process Temperature and Time on the Properties of
Microwave Plasma Nitrided Ti-6Al-4V Alloy |
title_full_unstemmed |
Effects of Process Temperature and Time on the Properties of
Microwave Plasma Nitrided Ti-6Al-4V Alloy |
title_sort |
effects of process temperature and time on the properties of
microwave plasma nitrided ti-6al-4v alloy |
publisher |
Universiti Putra Malaysia |
publishDate |
2013 |
url |
http://eprints.utem.edu.my/id/eprint/10951/1/pertanika_yy2013.pdf http://eprints.utem.edu.my/id/eprint/10951/ http://www.pertanika.upm.edu.my/JST.php |
_version_ |
1665905442186854400 |