Automatic room temperature control
This project proposes an automatic room temperature controller, which uses the difference between the outside and inside room temperature. The difference is assumed to affect the compressor speed in order to achieve the desired set point. The frequency of the speed compressor is also taken into acco...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2013
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/6667/1/24p%20LIZAWATI%20JAAFAR.pdf http://eprints.uthm.edu.my/6667/2/LIZAWATI%20JAAFAR%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/6667/3/LIZAWATI%20JAAFAR%20WATERMARK.pdf http://eprints.uthm.edu.my/6667/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tun Hussein Onn Malaysia |
Language: | English English English |
id |
my.uthm.eprints.6667 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.66672022-03-14T01:44:05Z http://eprints.uthm.edu.my/6667/ Automatic room temperature control Jaafar, Lizawati TJ Mechanical engineering and machinery TJ212-225 Control engineering systems. Automatic machinery (General) This project proposes an automatic room temperature controller, which uses the difference between the outside and inside room temperature. The difference is assumed to affect the compressor speed in order to achieve the desired set point. The frequency of the speed compressor is also taken into account. The project involves finding the mathematical model of an air conditioning system, designing a controller and performing a simulation to analyse the performance of the designed controller using Matlab/Simulink. The controller is based on adaptive fuzzy to control the temperature room. The result shows that the controller is able to follow the input reference and the output response of adaptive fuzzy control has better tracking performance. The developed system is hoped to address the issue of high cost electricity. 2013-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/6667/1/24p%20LIZAWATI%20JAAFAR.pdf text en http://eprints.uthm.edu.my/6667/2/LIZAWATI%20JAAFAR%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/6667/3/LIZAWATI%20JAAFAR%20WATERMARK.pdf Jaafar, Lizawati (2013) Automatic room temperature control. Masters thesis, Universiti Tun Hussein Malaysia. |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English English English |
topic |
TJ Mechanical engineering and machinery TJ212-225 Control engineering systems. Automatic machinery (General) |
spellingShingle |
TJ Mechanical engineering and machinery TJ212-225 Control engineering systems. Automatic machinery (General) Jaafar, Lizawati Automatic room temperature control |
description |
This project proposes an automatic room temperature controller, which uses the difference between the outside and inside room temperature. The difference is assumed to affect the compressor speed in order to achieve the desired set point. The frequency of the speed compressor is also taken into account. The project involves finding the mathematical model of an air conditioning system, designing a controller and performing a simulation to analyse the performance of the designed controller using Matlab/Simulink. The controller is based on adaptive fuzzy to control the temperature room. The result shows that the controller is able to follow the input reference and the output response of adaptive fuzzy control has better tracking performance. The developed system is hoped to address the issue of high cost electricity. |
format |
Thesis |
author |
Jaafar, Lizawati |
author_facet |
Jaafar, Lizawati |
author_sort |
Jaafar, Lizawati |
title |
Automatic room temperature control |
title_short |
Automatic room temperature control |
title_full |
Automatic room temperature control |
title_fullStr |
Automatic room temperature control |
title_full_unstemmed |
Automatic room temperature control |
title_sort |
automatic room temperature control |
publishDate |
2013 |
url |
http://eprints.uthm.edu.my/6667/1/24p%20LIZAWATI%20JAAFAR.pdf http://eprints.uthm.edu.my/6667/2/LIZAWATI%20JAAFAR%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/6667/3/LIZAWATI%20JAAFAR%20WATERMARK.pdf http://eprints.uthm.edu.my/6667/ |
_version_ |
1738581519831662592 |