Shear capacity steel fibre reinforced concrete composite slab

This thesis present the results of combined bending and shear test on composite slabs with steel fibres (SFs) in-situ concrete topping. Mechanical properties of steel fibre reinforced concrete (SFRC) were first determined by varying the fibres dosage from 0.50% to 1.25%. The test results show that t...

Full description

Saved in:
Bibliographic Details
Main Author: Che Bakar, Mohd. Basri
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/16680/5/MohdBasriCheBakarMFKA2010.pdf
http://eprints.utm.my/id/eprint/16680/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.16680
record_format eprints
spelling my.utm.166802018-05-27T06:35:09Z http://eprints.utm.my/id/eprint/16680/ Shear capacity steel fibre reinforced concrete composite slab Che Bakar, Mohd. Basri TA Engineering (General). Civil engineering (General) This thesis present the results of combined bending and shear test on composite slabs with steel fibres (SFs) in-situ concrete topping. Mechanical properties of steel fibre reinforced concrete (SFRC) were first determined by varying the fibres dosage from 0.50% to 1.25%. The test results show that there was not much improvement of the SFRC properties for steel fibres dosage of 1.0% and 1.25%. Apart from that, strong correlations were found between the concrete splitting tensile strength, compressive cube strength and flexural strength of SFRC. Following this, SFRC with 1.0% dosage was cast onto precast slab with different surface roughness. The SFRC replaced the conventional method using cast in-situ reinforced concrete topping. The experimental results on its ultimate shear capacity were further compared with previous research, and a parametric equation was proposed in predicting the interface shear strength using SFRC as concrete topping. The results shows that the ultimate shear capacity were 16.69% and 13.47% higher than the calculated value for the exposed aggregate and longitudinal roughened surface roughness, respectively. However, they were 15.23% and 17.56% lower than the smooth as-cast surface specimen with conventional reinforced concrete topping, respectively. As for the interface shear strength, the surface roughened in the longitudinal direction was the highest with 2.17 N/mm2. Further comparison was made with BS 8110 and Eurocode 2 and the results show that they were higher than the minimum value provided in both codes. The finding also suggested that surface roughened in the longitudinal direction was better than the other specimens with SFRC topping in terms of interface bonding. 2010-12 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/16680/5/MohdBasriCheBakarMFKA2010.pdf Che Bakar, Mohd. Basri (2010) Shear capacity steel fibre reinforced concrete composite slab. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Che Bakar, Mohd. Basri
Shear capacity steel fibre reinforced concrete composite slab
description This thesis present the results of combined bending and shear test on composite slabs with steel fibres (SFs) in-situ concrete topping. Mechanical properties of steel fibre reinforced concrete (SFRC) were first determined by varying the fibres dosage from 0.50% to 1.25%. The test results show that there was not much improvement of the SFRC properties for steel fibres dosage of 1.0% and 1.25%. Apart from that, strong correlations were found between the concrete splitting tensile strength, compressive cube strength and flexural strength of SFRC. Following this, SFRC with 1.0% dosage was cast onto precast slab with different surface roughness. The SFRC replaced the conventional method using cast in-situ reinforced concrete topping. The experimental results on its ultimate shear capacity were further compared with previous research, and a parametric equation was proposed in predicting the interface shear strength using SFRC as concrete topping. The results shows that the ultimate shear capacity were 16.69% and 13.47% higher than the calculated value for the exposed aggregate and longitudinal roughened surface roughness, respectively. However, they were 15.23% and 17.56% lower than the smooth as-cast surface specimen with conventional reinforced concrete topping, respectively. As for the interface shear strength, the surface roughened in the longitudinal direction was the highest with 2.17 N/mm2. Further comparison was made with BS 8110 and Eurocode 2 and the results show that they were higher than the minimum value provided in both codes. The finding also suggested that surface roughened in the longitudinal direction was better than the other specimens with SFRC topping in terms of interface bonding.
format Thesis
author Che Bakar, Mohd. Basri
author_facet Che Bakar, Mohd. Basri
author_sort Che Bakar, Mohd. Basri
title Shear capacity steel fibre reinforced concrete composite slab
title_short Shear capacity steel fibre reinforced concrete composite slab
title_full Shear capacity steel fibre reinforced concrete composite slab
title_fullStr Shear capacity steel fibre reinforced concrete composite slab
title_full_unstemmed Shear capacity steel fibre reinforced concrete composite slab
title_sort shear capacity steel fibre reinforced concrete composite slab
publishDate 2010
url http://eprints.utm.my/id/eprint/16680/5/MohdBasriCheBakarMFKA2010.pdf
http://eprints.utm.my/id/eprint/16680/
_version_ 1643646630226821120