Mechanical capabilities and fire endurance of rural rubber latex modified concrete
Compressive, indirect tensile, and flexural strengths characteristics of natural rubber latex modified concrete (NRLMC) were studied and reported — Part I. In addition, a comparative investigation between normal concrete (NC) and NRLMC, conducted on fire endurance was also presented — Part II. Norma...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Wiley-Blackwell Publishing Inc
2011
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/45036/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.45036 |
---|---|
record_format |
eprints |
spelling |
my.utm.450362017-09-28T07:05:04Z http://eprints.utm.my/id/eprint/45036/ Mechanical capabilities and fire endurance of rural rubber latex modified concrete Ismail, Mohammad Muhammad, Bala Yusuf, Abdirahman Ali Majid, Zaiton Ismail, Mohamed ElGelany TA Engineering (General). Civil engineering (General) Compressive, indirect tensile, and flexural strengths characteristics of natural rubber latex modified concrete (NRLMC) were studied and reported — Part I. In addition, a comparative investigation between normal concrete (NC) and NRLMC, conducted on fire endurance was also presented — Part II. Normal and modified elements containing latex–water ratios within 0–10% were prepared and cured in accordance with the Japan Industrial Standard. Fire endurance capacity was assessed at five temperature levels; ambient temperature (27 °C), 150, 300, 500, and 800 °C. However, elevated heating (800–1300 °C) was further applied for the purpose of monitoring behavior at the verge of disintegration. Specimens were allowed to cool in the oven prior to compressive strength tests until room temperature is attained. Test results indicate that significant mechanical capabilities could be achieved by the inclusion of an appropriate quantity of latex concentrate and proper selection of befitting curing regime. Interestingly, the superiority of NRLMC over NC is maintained even under fire, up to the critical limit of latex-film capability performance. Wiley-Blackwell Publishing Inc 2011 Article PeerReviewed Ismail, Mohammad and Muhammad, Bala and Yusuf, Abdirahman Ali and Majid, Zaiton and Ismail, Mohamed ElGelany (2011) Mechanical capabilities and fire endurance of rural rubber latex modified concrete. Canadian Journal of Civil Engineering, 38 (6). pp. 661-668. ISSN 0315-1468 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Ismail, Mohammad Muhammad, Bala Yusuf, Abdirahman Ali Majid, Zaiton Ismail, Mohamed ElGelany Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
description |
Compressive, indirect tensile, and flexural strengths characteristics of natural rubber latex modified concrete (NRLMC) were studied and reported — Part I. In addition, a comparative investigation between normal concrete (NC) and NRLMC, conducted on fire endurance was also presented — Part II. Normal and modified elements containing latex–water ratios within 0–10% were prepared and cured in accordance with the Japan Industrial Standard. Fire endurance capacity was assessed at five temperature levels; ambient temperature (27 °C), 150, 300, 500, and 800 °C. However, elevated heating (800–1300 °C) was further applied for the purpose of monitoring behavior at the verge of disintegration. Specimens were allowed to cool in the oven prior to compressive strength tests until room temperature is attained. Test results indicate that significant mechanical capabilities could be achieved by the inclusion of an appropriate quantity of latex concentrate and proper selection of befitting curing regime. Interestingly, the superiority of NRLMC over NC is maintained even under fire, up to the critical limit of latex-film capability performance. |
format |
Article |
author |
Ismail, Mohammad Muhammad, Bala Yusuf, Abdirahman Ali Majid, Zaiton Ismail, Mohamed ElGelany |
author_facet |
Ismail, Mohammad Muhammad, Bala Yusuf, Abdirahman Ali Majid, Zaiton Ismail, Mohamed ElGelany |
author_sort |
Ismail, Mohammad |
title |
Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
title_short |
Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
title_full |
Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
title_fullStr |
Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
title_full_unstemmed |
Mechanical capabilities and fire endurance of rural rubber latex modified concrete |
title_sort |
mechanical capabilities and fire endurance of rural rubber latex modified concrete |
publisher |
Wiley-Blackwell Publishing Inc |
publishDate |
2011 |
url |
http://eprints.utm.my/id/eprint/45036/ |
_version_ |
1643651623059193856 |