Automatic non invasive kidney volume measurement based on ultrasound image

Variation in kidney sizes can be associated with different kidney diseases. Ultrasound is widely used in the measurement of kidney size in diagnostic process. However, the precision and accuracy of the result is low due to the manual measurement that is highly dependent on the skill and experience o...

Full description

Saved in:
Bibliographic Details
Main Authors: Supriyanto, Eko, Wan Mahmud, Wan Mahani Hafizah, Wui, Yeoh Jing, Arooj, Adeela
Format: Conference or Workshop Item
Published: 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/45621/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.45621
record_format eprints
spelling my.utm.456212017-09-07T04:28:20Z http://eprints.utm.my/id/eprint/45621/ Automatic non invasive kidney volume measurement based on ultrasound image Supriyanto, Eko Wan Mahmud, Wan Mahani Hafizah Wui, Yeoh Jing Arooj, Adeela Q Science (General) R Medicine (General) Variation in kidney sizes can be associated with different kidney diseases. Ultrasound is widely used in the measurement of kidney size in diagnostic process. However, the precision and accuracy of the result is low due to the manual measurement that is highly dependent on the skill and experience of the doctor. Hence, an automatic measurement system should be developed and implemented to measure the kidney size automatically from ultrasound image. One such method has been developed here in this study. First, samples of kidney ultrasound image were collected and analysed. Then, programming algorithm in which a combination of noise filtering method such as Gabor filter, Wiener filter, and sharpening methods were used to suppress the speckle noise on the ultrasound image while preserving the fine details. The kidney was then segmented from the image using Level set method in which the zero level set was evolved to minimize the overall energy function depending on the gradient flow. Comparison of pixel value was used to determine the maximum and minimum point which was utilized to find the length, width, and thickness. At last, volume of the kidney was calculated using ellipsoid formula. Few samples have been tested and the result showed that this system is viable and able to assist in the diagnosis of early stage kidney diseases. 2011 Conference or Workshop Item PeerReviewed Supriyanto, Eko and Wan Mahmud, Wan Mahani Hafizah and Wui, Yeoh Jing and Arooj, Adeela (2011) Automatic non invasive kidney volume measurement based on ultrasound image. In: 15th WSEAS International Conference on Computers, 15 - 17 July 2011, Corfu Island, Greece.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic Q Science (General)
R Medicine (General)
spellingShingle Q Science (General)
R Medicine (General)
Supriyanto, Eko
Wan Mahmud, Wan Mahani Hafizah
Wui, Yeoh Jing
Arooj, Adeela
Automatic non invasive kidney volume measurement based on ultrasound image
description Variation in kidney sizes can be associated with different kidney diseases. Ultrasound is widely used in the measurement of kidney size in diagnostic process. However, the precision and accuracy of the result is low due to the manual measurement that is highly dependent on the skill and experience of the doctor. Hence, an automatic measurement system should be developed and implemented to measure the kidney size automatically from ultrasound image. One such method has been developed here in this study. First, samples of kidney ultrasound image were collected and analysed. Then, programming algorithm in which a combination of noise filtering method such as Gabor filter, Wiener filter, and sharpening methods were used to suppress the speckle noise on the ultrasound image while preserving the fine details. The kidney was then segmented from the image using Level set method in which the zero level set was evolved to minimize the overall energy function depending on the gradient flow. Comparison of pixel value was used to determine the maximum and minimum point which was utilized to find the length, width, and thickness. At last, volume of the kidney was calculated using ellipsoid formula. Few samples have been tested and the result showed that this system is viable and able to assist in the diagnosis of early stage kidney diseases.
format Conference or Workshop Item
author Supriyanto, Eko
Wan Mahmud, Wan Mahani Hafizah
Wui, Yeoh Jing
Arooj, Adeela
author_facet Supriyanto, Eko
Wan Mahmud, Wan Mahani Hafizah
Wui, Yeoh Jing
Arooj, Adeela
author_sort Supriyanto, Eko
title Automatic non invasive kidney volume measurement based on ultrasound image
title_short Automatic non invasive kidney volume measurement based on ultrasound image
title_full Automatic non invasive kidney volume measurement based on ultrasound image
title_fullStr Automatic non invasive kidney volume measurement based on ultrasound image
title_full_unstemmed Automatic non invasive kidney volume measurement based on ultrasound image
title_sort automatic non invasive kidney volume measurement based on ultrasound image
publishDate 2011
url http://eprints.utm.my/id/eprint/45621/
_version_ 1643651794468864000