Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability

The objective of this paper is to present the initial analysis on the energy recovery and controllability of the existing heat integrated fatty acid fractionation plant. From this initial analysis, the existing heat integrated fatty acid fractionation plant is analysed to know the either the existin...

Full description

Saved in:
Bibliographic Details
Main Authors: Abu Bakar, Suraya H., Abd. Hamid, Mohd. Kamaruddin, Wan Alwi, Sharifah Rafidah, A. Manan, Zainuddin
Format: Article
Published: Italian Association of Chemical Engineering - AIDIC 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55961/
http://dx.doi.org/10.3303/CET1545017
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.55961
record_format eprints
spelling my.utm.559612017-02-15T00:58:26Z http://eprints.utm.my/id/eprint/55961/ Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability Abu Bakar, Suraya H. Abd. Hamid, Mohd. Kamaruddin Wan Alwi, Sharifah Rafidah A. Manan, Zainuddin TP Chemical technology The objective of this paper is to present the initial analysis on the energy recovery and controllability of the existing heat integrated fatty acid fractionation plant. From this initial analysis, the existing heat integrated fatty acid fractionation plant is analysed to know the either the existing heat exchanger networks (HENs) satisfied the design criteria, or controllability criteria by using trade-off plot. According to the trade-off plot, if the existing HENs is better in terms of design criteria, then more efforts need to be invested to control the network. On the other hand, if the existing HENs is better in terms of controllability criteria, then more efforts need to be invested to reduce the energy consumption. In this study, the initial analysis means the value of the ΔTmin used for the current HENs is investigated and the controllability of the network is predicted by using trade-off plot. In order to investigate the value of the ΔTmin used for the current HENs, only the first two stages of the model-based flexible and operable HENs is used. In the Stage 1, the value of the ΔTmin is investigated by selecting the value of the ΔTmin ranging from 10 °C to 40 °C with the increment of 10 °C. Then, HEN is synthesized for the selected value of the ΔTmin. Once the networks have been synthesized, all candidates are transferred into a process simulator to test their process feasibility in Stage 2 where the unfeasible candidates will be eliminated. Then all feasible candidates will be predicted in terms of their controllability performance by using trade-off plot. Energy integrated fatty acid fractionation plant is used as a case study for this initial analysis. This paper only considers steady state controllability test without considering process dynamics Italian Association of Chemical Engineering - AIDIC 2015-10 Article PeerReviewed Abu Bakar, Suraya H. and Abd. Hamid, Mohd. Kamaruddin and Wan Alwi, Sharifah Rafidah and A. Manan, Zainuddin (2015) Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability. Chemical Engineering Transactions, 45 . pp. 97-102. ISSN 2283-9216 http://dx.doi.org/10.3303/CET1545017 DOI:10.3303/CET1545017
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Abu Bakar, Suraya H.
Abd. Hamid, Mohd. Kamaruddin
Wan Alwi, Sharifah Rafidah
A. Manan, Zainuddin
Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
description The objective of this paper is to present the initial analysis on the energy recovery and controllability of the existing heat integrated fatty acid fractionation plant. From this initial analysis, the existing heat integrated fatty acid fractionation plant is analysed to know the either the existing heat exchanger networks (HENs) satisfied the design criteria, or controllability criteria by using trade-off plot. According to the trade-off plot, if the existing HENs is better in terms of design criteria, then more efforts need to be invested to control the network. On the other hand, if the existing HENs is better in terms of controllability criteria, then more efforts need to be invested to reduce the energy consumption. In this study, the initial analysis means the value of the ΔTmin used for the current HENs is investigated and the controllability of the network is predicted by using trade-off plot. In order to investigate the value of the ΔTmin used for the current HENs, only the first two stages of the model-based flexible and operable HENs is used. In the Stage 1, the value of the ΔTmin is investigated by selecting the value of the ΔTmin ranging from 10 °C to 40 °C with the increment of 10 °C. Then, HEN is synthesized for the selected value of the ΔTmin. Once the networks have been synthesized, all candidates are transferred into a process simulator to test their process feasibility in Stage 2 where the unfeasible candidates will be eliminated. Then all feasible candidates will be predicted in terms of their controllability performance by using trade-off plot. Energy integrated fatty acid fractionation plant is used as a case study for this initial analysis. This paper only considers steady state controllability test without considering process dynamics
format Article
author Abu Bakar, Suraya H.
Abd. Hamid, Mohd. Kamaruddin
Wan Alwi, Sharifah Rafidah
A. Manan, Zainuddin
author_facet Abu Bakar, Suraya H.
Abd. Hamid, Mohd. Kamaruddin
Wan Alwi, Sharifah Rafidah
A. Manan, Zainuddin
author_sort Abu Bakar, Suraya H.
title Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
title_short Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
title_full Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
title_fullStr Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
title_full_unstemmed Initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
title_sort initial analysis on heat exchanger networks of fatty acid fractionation plant to optimize energy recovery and controllability
publisher Italian Association of Chemical Engineering - AIDIC
publishDate 2015
url http://eprints.utm.my/id/eprint/55961/
http://dx.doi.org/10.3303/CET1545017
_version_ 1643653953345290240