Eccentric loading on the tibial plate after knee replacement

Osseointegration is vital to the success of total knee arthroplasty. This intimate bone integration however, mostly occured on the femoral component but not on the tibial component. Failure to achieve sufficient primary fixation of the tibial component has been regarded as the major factor affecting...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Kadir, Mohammed Rafiq, Kamsah, N., Aziz, Z.
Format: Book Section
Published: Springer Berlin Heidelberg 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/6953/
https://link.springer.com/chapter/10.1007/978-3-540-69139-6_102
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.6953
record_format eprints
spelling my.utm.69532017-09-07T01:10:09Z http://eprints.utm.my/id/eprint/6953/ Eccentric loading on the tibial plate after knee replacement Abdul Kadir, Mohammed Rafiq Kamsah, N. Aziz, Z. TJ Mechanical engineering and machinery Osseointegration is vital to the success of total knee arthroplasty. This intimate bone integration however, mostly occured on the femoral component but not on the tibial component. Failure to achieve sufficient primary fixation of the tibial component has been regarded as the major factor affecting bone growth. The problem would be more apparent under eccentric loading which created complex rocking motions in both flexion and extension during gait. Fixation features in terms of protrusion on the undersurface of the tibial component include flange, screws and stem. In this study, the effect of three fixation features under physiological loading was analysed using non-linear contact finite element analysis. Three dimensional model of a human tibia was reconstructed from CT dataset. Three different tibial compartments — the cross-flange, the linear flange and the tapered cylindrical shaft — were modeled without the polymeric tibial insert. The component was then positioned on the tibial plateau and bone preparation was virtually simulated. Each model was then meshed with solid tetrahedrals and material properties were assigned to the bone and the prostheses. Coefficient of friction between the bone and the implant was set to 0.3. Pressure was applied on the medial plateau with magnitude corresponds to an eccentric load of 1250N. Non-linear contact analysis was performed on each of the three components, together with a validated micromotion algorithm to predict instability at the bone-implant interface. Results showed that the cross flange was the most stable under eccentric load with micromotion values did not exceed the threshold limit for osseointegration. Springer Berlin Heidelberg 2008 Book Section PeerReviewed Abdul Kadir, Mohammed Rafiq and Kamsah, N. and Aziz, Z. (2008) Eccentric loading on the tibial plate after knee replacement. In: IFMBE Proceedings. Springer Berlin Heidelberg, Germany, pp. 403-406. ISBN 1680-0737 https://link.springer.com/chapter/10.1007/978-3-540-69139-6_102
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Abdul Kadir, Mohammed Rafiq
Kamsah, N.
Aziz, Z.
Eccentric loading on the tibial plate after knee replacement
description Osseointegration is vital to the success of total knee arthroplasty. This intimate bone integration however, mostly occured on the femoral component but not on the tibial component. Failure to achieve sufficient primary fixation of the tibial component has been regarded as the major factor affecting bone growth. The problem would be more apparent under eccentric loading which created complex rocking motions in both flexion and extension during gait. Fixation features in terms of protrusion on the undersurface of the tibial component include flange, screws and stem. In this study, the effect of three fixation features under physiological loading was analysed using non-linear contact finite element analysis. Three dimensional model of a human tibia was reconstructed from CT dataset. Three different tibial compartments — the cross-flange, the linear flange and the tapered cylindrical shaft — were modeled without the polymeric tibial insert. The component was then positioned on the tibial plateau and bone preparation was virtually simulated. Each model was then meshed with solid tetrahedrals and material properties were assigned to the bone and the prostheses. Coefficient of friction between the bone and the implant was set to 0.3. Pressure was applied on the medial plateau with magnitude corresponds to an eccentric load of 1250N. Non-linear contact analysis was performed on each of the three components, together with a validated micromotion algorithm to predict instability at the bone-implant interface. Results showed that the cross flange was the most stable under eccentric load with micromotion values did not exceed the threshold limit for osseointegration.
format Book Section
author Abdul Kadir, Mohammed Rafiq
Kamsah, N.
Aziz, Z.
author_facet Abdul Kadir, Mohammed Rafiq
Kamsah, N.
Aziz, Z.
author_sort Abdul Kadir, Mohammed Rafiq
title Eccentric loading on the tibial plate after knee replacement
title_short Eccentric loading on the tibial plate after knee replacement
title_full Eccentric loading on the tibial plate after knee replacement
title_fullStr Eccentric loading on the tibial plate after knee replacement
title_full_unstemmed Eccentric loading on the tibial plate after knee replacement
title_sort eccentric loading on the tibial plate after knee replacement
publisher Springer Berlin Heidelberg
publishDate 2008
url http://eprints.utm.my/id/eprint/6953/
https://link.springer.com/chapter/10.1007/978-3-540-69139-6_102
_version_ 1643644673917452288