Scatter radiation in the fluoroscopy-guided interventional room

Radiation scattered throughout the room during fluoroscopy-guided interventional (FGI) procedures was quantified at different locations using nanoDot optically stimulated luminescence dosemeters. All the tube angulation imaging shows that the radiation spectrum resembled a single peak distribution....

Full description

Saved in:
Bibliographic Details
Main Authors: Bohari, Asmah, Hashim, Suhairul, Mohd. Mustafa, Siti Norsyafiqah
Format: Article
Published: Oxford University Press 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/90800/
http://dx.doi.org/10.1093/rpd/ncz299
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.90800
record_format eprints
spelling my.utm.908002021-05-31T13:29:41Z http://eprints.utm.my/id/eprint/90800/ Scatter radiation in the fluoroscopy-guided interventional room Bohari, Asmah Hashim, Suhairul Mohd. Mustafa, Siti Norsyafiqah QC Physics Radiation scattered throughout the room during fluoroscopy-guided interventional (FGI) procedures was quantified at different locations using nanoDot optically stimulated luminescence dosemeters. All the tube angulation imaging shows that the radiation spectrum resembled a single peak distribution. The left anterior oblique 90° shows the highest single peak distribution (28.65 mSv/h). The single peak distribution for standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging was 13.32, 22.99 and 17.40 mSv/h, respectively. All tube angulation shows that the position of the interventional radiologist experienced a higher radiation level compared to other staffs. The doses of radiation varied widely around the perimeter of the patient's table and changed in accordance to imaging angles during procedures. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly among staff. Oxford University Press 2020-06-24 Article PeerReviewed Bohari, Asmah and Hashim, Suhairul and Mohd. Mustafa, Siti Norsyafiqah (2020) Scatter radiation in the fluoroscopy-guided interventional room. Radiation Protection Dosimetry, 188 (3). pp. 397-402. ISSN 0144-8420 http://dx.doi.org/10.1093/rpd/ncz299 DOI:10.1093/rpd/ncz299
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Bohari, Asmah
Hashim, Suhairul
Mohd. Mustafa, Siti Norsyafiqah
Scatter radiation in the fluoroscopy-guided interventional room
description Radiation scattered throughout the room during fluoroscopy-guided interventional (FGI) procedures was quantified at different locations using nanoDot optically stimulated luminescence dosemeters. All the tube angulation imaging shows that the radiation spectrum resembled a single peak distribution. The left anterior oblique 90° shows the highest single peak distribution (28.65 mSv/h). The single peak distribution for standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging was 13.32, 22.99 and 17.40 mSv/h, respectively. All tube angulation shows that the position of the interventional radiologist experienced a higher radiation level compared to other staffs. The doses of radiation varied widely around the perimeter of the patient's table and changed in accordance to imaging angles during procedures. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly among staff.
format Article
author Bohari, Asmah
Hashim, Suhairul
Mohd. Mustafa, Siti Norsyafiqah
author_facet Bohari, Asmah
Hashim, Suhairul
Mohd. Mustafa, Siti Norsyafiqah
author_sort Bohari, Asmah
title Scatter radiation in the fluoroscopy-guided interventional room
title_short Scatter radiation in the fluoroscopy-guided interventional room
title_full Scatter radiation in the fluoroscopy-guided interventional room
title_fullStr Scatter radiation in the fluoroscopy-guided interventional room
title_full_unstemmed Scatter radiation in the fluoroscopy-guided interventional room
title_sort scatter radiation in the fluoroscopy-guided interventional room
publisher Oxford University Press
publishDate 2020
url http://eprints.utm.my/id/eprint/90800/
http://dx.doi.org/10.1093/rpd/ncz299
_version_ 1702169603493330944