Transient analysis of an optimized robust controller in a hydraulic system

An electro-hydraulic actuator (EHA) system is a prevalent mechanism in industrial sectors that required high force such as steel, automotive and aerospace industries. It is a challenging task to acquire precision when dealing with a system that can produce high force. Besides, since most of the mech...

Full description

Saved in:
Bibliographic Details
Main Authors: Chong, Chee Soon, Ghazali, Rozaimi, Chai, Mau Shern, Md. Sam, Yahaya, Has, Zulfatman
Format: Article
Published: Asian Research Publishing Network 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/97672/
http://www.arpnjournals.com/jeas/volume_15_2021.htm
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.97672
record_format eprints
spelling my.utm.976722022-10-25T10:32:59Z http://eprints.utm.my/id/eprint/97672/ Transient analysis of an optimized robust controller in a hydraulic system Chong, Chee Soon Ghazali, Rozaimi Chai, Mau Shern Md. Sam, Yahaya Has, Zulfatman TK Electrical engineering. Electronics Nuclear engineering An electro-hydraulic actuator (EHA) system is a prevalent mechanism in industrial sectors that required high force such as steel, automotive and aerospace industries. It is a challenging task to acquire precision when dealing with a system that can produce high force. Besides, since most of the mechanical actuator performance varies with time, it is even difficult to ensure its robustness characteristic towards time. Therefore, this paper proposed the industrial’s well-known controller, which is the proportional-integral-derivative (PID) controller that can improve the precision and the robustness or the EHA system. Then, an enhanced PID controller, which is the fractional order PID (FOPID) controller will be applied. Both controllers are optimized using particle swarm optimization (PSO) algorithm. Then, this paper will focus to analyse the transient response performance of both controllers through the step and multiple-step response. As a result, it is observed that the precision and robustness characteristic of the FOPID is greater than the PID controller. Asian Research Publishing Network 2021 Article PeerReviewed Chong, Chee Soon and Ghazali, Rozaimi and Chai, Mau Shern and Md. Sam, Yahaya and Has, Zulfatman (2021) Transient analysis of an optimized robust controller in a hydraulic system. ARPN Journal of Engineering and Applied Sciences, 16 (15). pp. 1567-1571. ISSN 1819-6608 http://www.arpnjournals.com/jeas/volume_15_2021.htm NA
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chong, Chee Soon
Ghazali, Rozaimi
Chai, Mau Shern
Md. Sam, Yahaya
Has, Zulfatman
Transient analysis of an optimized robust controller in a hydraulic system
description An electro-hydraulic actuator (EHA) system is a prevalent mechanism in industrial sectors that required high force such as steel, automotive and aerospace industries. It is a challenging task to acquire precision when dealing with a system that can produce high force. Besides, since most of the mechanical actuator performance varies with time, it is even difficult to ensure its robustness characteristic towards time. Therefore, this paper proposed the industrial’s well-known controller, which is the proportional-integral-derivative (PID) controller that can improve the precision and the robustness or the EHA system. Then, an enhanced PID controller, which is the fractional order PID (FOPID) controller will be applied. Both controllers are optimized using particle swarm optimization (PSO) algorithm. Then, this paper will focus to analyse the transient response performance of both controllers through the step and multiple-step response. As a result, it is observed that the precision and robustness characteristic of the FOPID is greater than the PID controller.
format Article
author Chong, Chee Soon
Ghazali, Rozaimi
Chai, Mau Shern
Md. Sam, Yahaya
Has, Zulfatman
author_facet Chong, Chee Soon
Ghazali, Rozaimi
Chai, Mau Shern
Md. Sam, Yahaya
Has, Zulfatman
author_sort Chong, Chee Soon
title Transient analysis of an optimized robust controller in a hydraulic system
title_short Transient analysis of an optimized robust controller in a hydraulic system
title_full Transient analysis of an optimized robust controller in a hydraulic system
title_fullStr Transient analysis of an optimized robust controller in a hydraulic system
title_full_unstemmed Transient analysis of an optimized robust controller in a hydraulic system
title_sort transient analysis of an optimized robust controller in a hydraulic system
publisher Asian Research Publishing Network
publishDate 2021
url http://eprints.utm.my/id/eprint/97672/
http://www.arpnjournals.com/jeas/volume_15_2021.htm
_version_ 1748180492090343424