RCM Analysis of Process Equipment: A Case Study on Heat Exchanger

The traditional approach of maintenance emphasis on individual equipment. This practice has caused a number of problems. Among the problems are the maintenance actions are conservative in nature, thinking failure of parts are equals and performing maintenance actions to become totally reactive. Reli...

Full description

Saved in:
Bibliographic Details
Main Authors: A Majid, Mohd Amin, Muhammad, Masdi, Nur IllaniYen@Yem,, Nur IllaniYen@Yem
Format: Citation Index Journal
Published: Asian Network for Scientific Information 2010
Subjects:
Online Access:http://eprints.utp.edu.my/1866/1/RCM-23672-23672.pdf
http://eprints.utp.edu.my/1866/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.1866
record_format eprints
spelling my.utp.eprints.18662017-01-19T08:24:30Z RCM Analysis of Process Equipment: A Case Study on Heat Exchanger A Majid, Mohd Amin Muhammad, Masdi Nur IllaniYen@Yem,, Nur IllaniYen@Yem, TJ Mechanical engineering and machinery The traditional approach of maintenance emphasis on individual equipment. This practice has caused a number of problems. Among the problems are the maintenance actions are conservative in nature, thinking failure of parts are equals and performing maintenance actions to become totally reactive. Reliability centered maintenance (RCM) was introduced to address these problems. This paper focused on RCM analysis applied to process equipment with heat exchangers as a case study. The seven steps of RCM analysis addressing DEFINE, ANALYSE and ACT are discussed. Results indicate that RCM could assist in identifying the functional failures, causes of failures and risk ranking which are linked to corrosion rates and remaining life of the heat exchangers. Based on the results of the RCM analysis, the next inspec Asian Network for Scientific Information 2010 Citation Index Journal PeerReviewed application/pdf http://eprints.utp.edu.my/1866/1/RCM-23672-23672.pdf A Majid, Mohd Amin and Muhammad, Masdi and Nur IllaniYen@Yem,, Nur IllaniYen@Yem, (2010) RCM Analysis of Process Equipment: A Case Study on Heat Exchanger. [Citation Index Journal] http://eprints.utp.edu.my/1866/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
A Majid, Mohd Amin
Muhammad, Masdi
Nur IllaniYen@Yem,, Nur IllaniYen@Yem,
RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
description The traditional approach of maintenance emphasis on individual equipment. This practice has caused a number of problems. Among the problems are the maintenance actions are conservative in nature, thinking failure of parts are equals and performing maintenance actions to become totally reactive. Reliability centered maintenance (RCM) was introduced to address these problems. This paper focused on RCM analysis applied to process equipment with heat exchangers as a case study. The seven steps of RCM analysis addressing DEFINE, ANALYSE and ACT are discussed. Results indicate that RCM could assist in identifying the functional failures, causes of failures and risk ranking which are linked to corrosion rates and remaining life of the heat exchangers. Based on the results of the RCM analysis, the next inspec
format Citation Index Journal
author A Majid, Mohd Amin
Muhammad, Masdi
Nur IllaniYen@Yem,, Nur IllaniYen@Yem,
author_facet A Majid, Mohd Amin
Muhammad, Masdi
Nur IllaniYen@Yem,, Nur IllaniYen@Yem,
author_sort A Majid, Mohd Amin
title RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
title_short RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
title_full RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
title_fullStr RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
title_full_unstemmed RCM Analysis of Process Equipment: A Case Study on Heat Exchanger
title_sort rcm analysis of process equipment: a case study on heat exchanger
publisher Asian Network for Scientific Information
publishDate 2010
url http://eprints.utp.edu.my/1866/1/RCM-23672-23672.pdf
http://eprints.utp.edu.my/1866/
_version_ 1738655157904736256