Effect of Cᵣ on the performance of Fredlund and Xing (1994)'s equation in best fitting soil-water characteristic curve data

Fredlund and Xing (1994)'s equation is one of most popular equations in best fitting the soil-water characteristic curve (SWCC) data. It is commonly considered that the parameters of the equation such as a, n and m are the fitting parameters and Cr is an input value, which is commonly recommend...

全面介紹

Saved in:
書目詳細資料
Main Authors: Wang, Shijun, Li, Wanwei, Chen, Ziyun, Tian, Gang, Dai, Guoliang, Zhai, Qian, Rahardjo, Harianto
其他作者: School of Civil and Environmental Engineering
格式: Article
語言:English
出版: 2023
主題:
在線閱讀:https://hdl.handle.net/10356/164200
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Fredlund and Xing (1994)'s equation is one of most popular equations in best fitting the soil-water characteristic curve (SWCC) data. It is commonly considered that the parameters of the equation such as a, n and m are the fitting parameters and Cr is an input value, which is commonly recommended that Cr to be1500 kPa or 3000 kPa. Based on the analysis in this paper, it is observed that setting Cr to be equal to 1500 kPa or 3000 kPa may downgrade the performance of Fredlund and Xing (1994)'s equation in best fitting the SWCC data of soils with a high air-entry value (AEV). It is recommended the air-entry value (AEV) of the soil is roughly estimated before the best fitting process and set Cr to be 100 times of the estimated AEV for the best regression analysis.