Testing, modelling and analysis of full-scale cold-formed steel center-sheathed shear walls in fire
Cold-formed steel center-sheathed shear wall (CFSCSSW) is an innovative shear wall applied to multi-story cold-formed steel buildings. In this study, six tests were carried out on CFSCSSWs, including one room temperature test to obtain load-bearing capacity and five fire tests to investigate the inf...