Condition monitoring and fault diagnosis of fluid power system

This report is concerned with the condition monitoring and fault diagnosis of fluid power components. The hydraulic systems involved were an oil hydraulic system and a water hydraulic system. The oil/water hydraulic system consisted of power pack, directional control valves, hydraulic motor and hydr...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Yu, Li.
مؤلفون آخرون: Chua, Patrick Soon Keong
التنسيق: Theses and Dissertations
منشور في: 2008
الموضوعات:
الوصول للمادة أونلاين:http://hdl.handle.net/10356/5507
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
id sg-ntu-dr.10356-5507
record_format dspace
spelling sg-ntu-dr.10356-55072023-03-11T17:05:25Z Condition monitoring and fault diagnosis of fluid power system Yu, Li. Chua, Patrick Soon Keong School of Mechanical and Production Engineering Lim, Geok Hian DRNTU::Engineering::Mechanical engineering::Fluid mechanics This report is concerned with the condition monitoring and fault diagnosis of fluid power components. The hydraulic systems involved were an oil hydraulic system and a water hydraulic system. The oil/water hydraulic system consisted of power pack, directional control valves, hydraulic motor and hydraulic cylinder. The method employed for condition monitoring was vibration measurements. Amplitude spectrum analyses were used to analyze the running condition of the hydraulic cylinder and motor. The experiments included developing the procedures for fault detection on leakage through seal and piston cracks. LabVEEW, a graphical programming language, was used to form an effective analysis of the amplitude and power spectra. It integrates data acquisition, analysis and presentation into one system. Master of Engineering (MPE) 2008-09-17T10:52:19Z 2008-09-17T10:52:19Z 2000 2000 Thesis http://hdl.handle.net/10356/5507 Nanyang Technological University application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
topic DRNTU::Engineering::Mechanical engineering::Fluid mechanics
spellingShingle DRNTU::Engineering::Mechanical engineering::Fluid mechanics
Yu, Li.
Condition monitoring and fault diagnosis of fluid power system
description This report is concerned with the condition monitoring and fault diagnosis of fluid power components. The hydraulic systems involved were an oil hydraulic system and a water hydraulic system. The oil/water hydraulic system consisted of power pack, directional control valves, hydraulic motor and hydraulic cylinder. The method employed for condition monitoring was vibration measurements. Amplitude spectrum analyses were used to analyze the running condition of the hydraulic cylinder and motor. The experiments included developing the procedures for fault detection on leakage through seal and piston cracks. LabVEEW, a graphical programming language, was used to form an effective analysis of the amplitude and power spectra. It integrates data acquisition, analysis and presentation into one system.
author2 Chua, Patrick Soon Keong
author_facet Chua, Patrick Soon Keong
Yu, Li.
format Theses and Dissertations
author Yu, Li.
author_sort Yu, Li.
title Condition monitoring and fault diagnosis of fluid power system
title_short Condition monitoring and fault diagnosis of fluid power system
title_full Condition monitoring and fault diagnosis of fluid power system
title_fullStr Condition monitoring and fault diagnosis of fluid power system
title_full_unstemmed Condition monitoring and fault diagnosis of fluid power system
title_sort condition monitoring and fault diagnosis of fluid power system
publishDate 2008
url http://hdl.handle.net/10356/5507
_version_ 1761781570522316800