Early wound healing and refractive response of different pocket configurations following presbyopic inlay implantation

Background: Presbyopic inlays have mostly been implanted under a corneal flap. Implantation in a pocket has advantages including less postoperative dry eye and neurotrophic effect, and better biomechanical corneal stability. This study investigated the effect of different pocket and flocket dimensio...

全面介紹

Saved in:
書目詳細資料
Main Authors: Konstantopoulos, Aris, Liu, Yu-Chi, Teo, Ericia Pei Wen, Lwin, Nyein Chan, Yam, Gary Hin Fai, Mehta, Jodhbir Singh
其他作者: Lai, Jui-Yang
格式: Article
語言:English
出版: 2017
主題:
在線閱讀:https://hdl.handle.net/10356/83498
http://hdl.handle.net/10220/42631
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Background: Presbyopic inlays have mostly been implanted under a corneal flap. Implantation in a pocket has advantages including less postoperative dry eye and neurotrophic effect, and better biomechanical corneal stability. This study investigated the effect of different pocket and flocket dimensions on corneal stability and refractive power after Raindrop™ implantation, and the associated wound healing response. Methodology: Ten New Zealand White rabbits had bilateral pocket Raindrop™ implantation. Eyes were allocated to 4 groups: pockets with 4mm, 6mm, and 8mm diameters, and 8mm flocket. They were examined pre-operatively, at day 1, weeks 1, 2, 3 and 4 post-surgery with anterior segment optical coherence tomography, corneal topography and in-vivo confocal microscopy. After euthanasia (week 4), CD11b, heat shock protein (HSP) 47 and fibronectin corneal immunohistochemistry was performed. Results: Corneal thickness (mean±SD) increased from 360.0±16.2μm pre-operatively to 383.9±32.5, 409.4±79.3, 393.6±35.2, 396.4±50.7 and 405±20.3μm on day 1, weeks 1,2,3 and 4 respectively (p<0.008, all time-points). Corneal refractive power increased by 11.1±5.5, 7.5±2.5, 7.5±3.1, 7.0±3.6 and 6.3±2.9D (p<0.001). Corneal astigmatism increased from 1.1±0.3D to 2.3±1.6, 1.7±0.7, 1.8±1.0, 1.6±0.9 and 1.6±0.9D respectively (p = 0.033). CT, refractive power change and astigmatism were not different between groups. The 8mm pocket and 8mm flocket groups had the least stromal keratocyte reflectivity. CD11b, fibronectin or HSP47 weren’t detected. Conclusions: Anatomical and refractive stability was achieved by 1 week; the outcomes were not affected by pocket or flocket configuration. No scarring or inflammation was identified. The 8mm pocket and flocket showed the least keratocyte activation, suggesting they might be the preferred configuration.