Deadbeat control for a single-phase cascaded H-bridge rectifier with voltage balancing modulation
The model predictive control (MPC) is a promising control method for cascaded H-bridge (CHB) rectifiers. One well-known MPC method is the finite-control-set MPC (FCS-MPC). However, three main issues arise in FCS-MPC: heavy computational burden, low steady-state performance, and time-consuming tuning...
Saved in:
Main Authors: | , , , |
---|---|
其他作者: | |
格式: | Article |
語言: | English |
出版: |
2018
|
主題: | |
在線閱讀: | https://hdl.handle.net/10356/88271 http://hdl.handle.net/10220/45677 |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
機構: | Nanyang Technological University |
語言: | English |
總結: | The model predictive control (MPC) is a promising control method for cascaded H-bridge (CHB) rectifiers. One well-known MPC method is the finite-control-set MPC (FCS-MPC). However, three main issues arise in FCS-MPC: heavy computational burden, low steady-state performance, and time-consuming tuning work of weighting factor. Here, an alternative MPC method, deadbeat (DB) control with a capability of voltage balance, has been proposed for a single-phase CHB rectifier. The proposed method is based on the DB solution to obtain zero current error at the sampling instant and the use of a redundancy-based modulation strategy for voltage balance, leading to the ease of controller design and elimination of tuning work. The proposed method has been evaluated against FCS-MPC method on a single-phase three-cell CHB rectifier. The experimental results show that a reduced computational burden, an improved steady-state performance, and a comparable dynamic response can be achieved in the proposed method in comparison with FCS-MPC method. |
---|