Transient state estimation with the Bergeron transmission line model

© TÜBİTAK. Transient state estimation (TSE) was used to determine the state values that have no measurement equipment placed in an electric power system with transient phenomena. Previous papers used the PI model for TSE with a short transmission line, but longer lines require the development of alg...

全面介紹

Saved in:
書目詳細資料
Main Authors: Suyaroj N., Premrudeepreechacharn S., Watson N.
格式: 雜誌
出版: 2017
在線閱讀:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017386713&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40995
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id th-cmuir.6653943832-40995
record_format dspace
spelling th-cmuir.6653943832-409952017-09-28T04:14:56Z Transient state estimation with the Bergeron transmission line model Suyaroj N. Premrudeepreechacharn S. Watson N. © TÜBİTAK. Transient state estimation (TSE) was used to determine the state values that have no measurement equipment placed in an electric power system with transient phenomena. Previous papers used the PI model for TSE with a short transmission line, but longer lines require the development of algorithms that include the distributed parameters of transmission lines with the Bergeron model. The test system was a 10-bus power system. The simulated transient was caused by a fault event, resulting in different persistent voltage drops that ranged from 10% to 90% at selected buses. In addition, noises were applied to evaluate the algorithm, which was defined to be normally distributed. Noise at 1%, 2%, and 3% was added to all measurements. The results showed that the developed TSE provided good estimation at the locations that had no measurement equipment for distributed transmission lines. 2017-09-28T04:14:56Z 2017-09-28T04:14:56Z 2017-01-01 Journal 13000632 2-s2.0-85017386713 10.3906/elk-1507-41 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017386713&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40995
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © TÜBİTAK. Transient state estimation (TSE) was used to determine the state values that have no measurement equipment placed in an electric power system with transient phenomena. Previous papers used the PI model for TSE with a short transmission line, but longer lines require the development of algorithms that include the distributed parameters of transmission lines with the Bergeron model. The test system was a 10-bus power system. The simulated transient was caused by a fault event, resulting in different persistent voltage drops that ranged from 10% to 90% at selected buses. In addition, noises were applied to evaluate the algorithm, which was defined to be normally distributed. Noise at 1%, 2%, and 3% was added to all measurements. The results showed that the developed TSE provided good estimation at the locations that had no measurement equipment for distributed transmission lines.
format Journal
author Suyaroj N.
Premrudeepreechacharn S.
Watson N.
spellingShingle Suyaroj N.
Premrudeepreechacharn S.
Watson N.
Transient state estimation with the Bergeron transmission line model
author_facet Suyaroj N.
Premrudeepreechacharn S.
Watson N.
author_sort Suyaroj N.
title Transient state estimation with the Bergeron transmission line model
title_short Transient state estimation with the Bergeron transmission line model
title_full Transient state estimation with the Bergeron transmission line model
title_fullStr Transient state estimation with the Bergeron transmission line model
title_full_unstemmed Transient state estimation with the Bergeron transmission line model
title_sort transient state estimation with the bergeron transmission line model
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017386713&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40995
_version_ 1681421920263733248