Nitrogen removal by a combined subsurface vertical down-flow and up-flow constructed wetland system

A subsurface vertical up-flow followed by down-flow constructed wetland system was used to treat anaerobic digester effluent from pig-farm wastewater. The system consists of two beds connected in series and have equal size of 1.2 × 1.2 × 0.6 m (W × L × D). The first bed was planted with Typha angust...